首页> 外文期刊>Journal of the air & waste management association >Comparison of measured total suspended particulate matter concentrations using tapered element oscillating microbalance and a total suspended particulate sampler
【24h】

Comparison of measured total suspended particulate matter concentrations using tapered element oscillating microbalance and a total suspended particulate sampler

机译:使用锥形振荡微天平和总悬浮颗粒物采样器对测得的总悬浮颗粒物浓度进行比较

获取原文
获取原文并翻译 | 示例
       

摘要

A comparison of the concentration of the total suspended particulate (TSP) matter measured by the tapered element oscillating microbalance (TEOM) monitor and the isokinetic TSP samplers developed at the University of Illinois was carried out in several types of confinement livestock buildings. In a majority of the measurements done, the dust concentration measured by the TEOM monitor was lower than the University of Illinois at Urbana-Champaign (UIUC) isokinetic TSP sampler; the TEOM monitor tended to underestimate the total dust concentration by as much as 54%. The difference in measurements can be attributed to the sampling efficiency of the TEOM monitor sampling head and the loss of some semivolatile compounds and particle-bound water because of heating of the TEOM monitor sampling.stream to 50 degrees C. Although several articles in the literature supported the latter argument, this study did not investigate the effect of heating the sampling stream or the effect of moisture on the relative difference in dust concentration measurements. The model that best describes the relationship between the two methods was site specific, that is, the linear regression model was applicable only to four of the sites monitored. The measured total dust concentration in livestock buildings range from similar to 300 to 4000 mu g/m(3); a higher correlation coefficient between TEOM-TSP and UIUC-TSP monitors was obtained in swine facilities than those obtained in a laying facility.
机译:在几种类型的封闭式畜牧建筑中,对由锥形元素振荡微量天平(TEOM)监测器和伊利诺伊大学开发的等速TSP采样器测量的总悬浮颗粒(TSP)物质浓度进行了比较。在完成的大多数测量中,TEOM监测器测得的粉尘浓度低于伊利诺伊大学香槟分校(UIUC)等速TSP采样器; TEOM监测仪往往低估了总灰尘浓度多达54%。测量值的差异可归因于TEOM监测器采样头的采样效率以及由于将TEOM监测器采样流加热到50摄氏度而导致的一些半挥发性化合物和颗粒结合水的损失。尽管文献中有几篇文章支持后一种观点,本研究没有研究加热采样流或水分对粉尘浓度测量相对差的影响。最能描述这两种方法之间关系的模型是特定于站点的,也就是说,线性回归模型仅适用于所监视的四个站点。畜牧建筑中测得的总粉尘浓度约为300至4000μg / m(3);在猪场设施中获得的TEOM-TSP和UIUC-TSP监视器之间的相关系数要比在产蛋场所获得的更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号