"High Clean DX" a dioxins removal technology for fly ash discharged from municipal solid waste (MSW) incinerators was developed. In the course of developing "High Clean DX," a rapid analytical technology for the dioxins concentration in fly ash was important. A simplified analytical technology for dioxins in fly ash using flame ionization detector gas chromatography has been developed by focusing on the simple volatilization behavior of organic compounds," This technology makes it possible to estimate the dioxins concentration of fly ash rapidly.
机译:开发了“ High Clean DX”二恶英去除技术,用于从城市固体废物(MSW)焚化炉中排放飞灰。在开发“ High Clean DX”的过程中,飞灰中二恶英浓度的快速分析技术非常重要。通过着眼于有机化合物的简单挥发行为,已经开发出了一种使用火焰电离检测器气相色谱法分析飞灰中二恶英的简化分析技术。”该技术使快速估算飞灰中二恶英的浓度成为可能。