首页> 外文期刊>Japanese Journal of Applied Physics. Part 2, Letters >Magnetometer Utilizing Cooled Normal Pickup Coil and High-T_c Superconducting Quantum Interference Device Picovoltmeter for Nondestructive Evaluation
【24h】

Magnetometer Utilizing Cooled Normal Pickup Coil and High-T_c Superconducting Quantum Interference Device Picovoltmeter for Nondestructive Evaluation

机译:利用冷却的正常拾取线圈和高T_c超导量子干涉仪皮伏计的磁力计进行无损评估

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A magnetometer utilizing a cooled normal pickup coil and a high-T_c superconducting quantum interference device (SQUID) picovoltmeter was applied to nondestructive evaluation in an unshielded environment. The pickup coil of copper wire was cooled to T = 77 K in order to decrease thermal noise from resistance. The magnetic field noise of the magnetometer was 130pT/Hz~(1/2) and 10 pT/Hz~(1/2) at 100 Hz and 1 kHz, respectively, for the pickup coil with a 4.4mm diameter. It was shown that the magnetometer could be moved in an unshielded environment without degradation of its performance. By moving the cooled pickup coil, we successfully detected a small crack on the backsurface of the Cu plate in an unshielded environment.
机译:将利用冷却的正常拾波线圈和高T_c超导量子干涉仪(SQUID)皮伏计的磁力计用于非屏蔽环境中的无损评估。铜线的拾波线圈冷却至T = 77 K,以减少电阻产生的热噪声。对于直径为4.4mm的拾波线圈,磁力计的磁场噪声在100 Hz和1 kHz时分别为130pT / Hz〜(1/2)和10pT / Hz〜(1/2)。结果表明,磁力计可以在不受屏蔽的环境中移动而不会降低其性能。通过移动冷却的拾波线圈,我们成功地在非屏蔽环境中检测到了铜板背面的小裂纹。