首页> 外文期刊>Iranian journal of chemistry & chemical engineering >Molecularly Imprinted Stir Bar Sorptive Extraction Coupled with High-Performance Liquid Chromatography for Trace Analysis of Diclofenac in Different Real Samples
【24h】

Molecularly Imprinted Stir Bar Sorptive Extraction Coupled with High-Performance Liquid Chromatography for Trace Analysis of Diclofenac in Different Real Samples

机译:分子印迹搅拌棒吸附萃取耦合,高性能液相色谱谱分析不同真实样品中的双氯芬酸

获取原文
获取原文并翻译 | 示例
           

摘要

A novel molecularly imprinted polymer coated stir bar has been used to selectively extract diclofenac (DFC) directly from real samples. DFC was used as template molecule for preparation of MIP coating. The effect of different parameters on the extraction efficiency were studied and the optimum conditions were established as: the absorption and desorption times were fixed at 10 min, stirring speed was 600 rpm, pH was adjusted to 5.1, amount of NaCl was 0.35 mol/L and extraction process was performed at a temperature of 45 °C. Under the optimum conditions, the linear range of method was 0.5- 500.0 μg/L for DFC and the detection limit was calculated to be 0.15 μg/L with an enrichment factor of 242 folds. The technique was successfully applied for the analysis of trace amounts of DFC in seawater and commercial tablet samples. The mean recoveries of spiking real samples with DFC at 10.0 μg/L level were between 94.2-100.0 % with a mean RSD of 0.7-4.6%.
机译:一种新的分子印迹聚合物涂层搅拌棒被用来直接从真正的样品中选择性地提取双氯芬酸(DFC)。 DFC用作模板分子以制备覆盖物。研究了不同参数对提取效率的影响,建立了最佳条件为:在10分钟内固定吸收和解吸时间,搅拌速度为600rpm,将pH调节至5.1,含量为0.35 mol / l萃取过程在45℃的温度下进行。在最佳条件下,对于DFC的方法的线性范围为0.5-500.0μg/ L,并且检测极限计算为0.15μg/ L,富集因子为242倍。该技术成功地应用于海水和商业片剂样品中痕量DFC的分析。使用DFC为10.0μg/ L水平的尖刺真实样品的平均回收率在94.2-100.0%之间,平均RSD为0.7-4.6%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号