摘要

The purpose of the experimental work described in this paper is the determination of the ventilation requirements in enclosures containing fuel cells such that, in the case of a small non catastrophic release, the H_2 concentration in air for zone 2 ATEX (2% v/v) is not exceeded. A full scale fuel cell was placed inside the experimental facility having 25 m3 volume. Three different leaks were investigated (40, 90 and 180 Nlt/min) and H_2 concentrations were measured at five locations inside the facility. Several vent areas were examined for the cases of natural ventilation. When natural ventilation failed to ensure H_2 concentrations less than 2% v/v in the facility, mechanical ventilation using two fans was investigated. Based on the experimental set up, it was found that natural ventilation is sufficient when the air-flow calculated from ATEX guidelines is higher than 0.009 m~3/s and the release flow rate corresponds to a non-catastrophic release, i.e. 40 Nlt/min. For higher release flow rates most of the ventilation configurations were not sufficient to maintain a H_2 concentration less than 2% v/v. All forced ventilation configurations examined (together with the free ventilation areas used) were sufficient to maintain a H_2 concentration below 2% v/v for 40 Nlt/min and 90 Nlt/min release flow rates. For the higher release flow rate of 180 Nlt/min, most of the forced ventilation configurations were insufficient.
机译:本文所述实验工作的目的是确定装有燃料电池的机柜中的通风要求,以便在少量非灾难性释放的情况下,区域2 ATEX(2%v / v)中空气中的H_2浓度)。将全尺寸燃料电池放置在容量为25 m3的实验设备内。研究了三种不同的泄漏(40、90和180 Nlt / min),并在设施内的五个位置测量了H_2的浓度。检查了几个通风口区域的自然通风情况。当自然通风无法确保设施中的H_2浓度低于2%v / v时,对使用两个风扇的机械通风进行了研究。根据实验设置,发现当根据ATEX准则计算的气流高于0.009 m〜3 / s且释放流速对应于非灾难性释放时,即40 Nlt /,自然通风就足够了。分钟对于更高的释放流速,大多数通风配置不足以维持H_2浓度低于2%v / v。检查的所有强制通风配置(以及所使用的自由通风区域)足以在40 Nlt / min和90 Nlt / min释放流速下将H_2浓度保持在2%v / v以下。对于更高的180 Nlt / min的释放流速,大多数强制通风配置不足。

著录项

  • 来源
    《International journal of hydrogen energy》 |2011年第3期|p.2478-2488|共11页
  • 作者单位

    Saipem Spa, QHSE Department, Kashagan (KZ) Trunklines Project, Via Leone Tolstoj 86, San Giuliano Milanese (MI), Italy;

    Department of Mechanical Nuclear and Production Engineering DIMNP, University o/Pisa, Largo Lazzarino, 2, Pisa, Italy;

    Department of Mechanical Nuclear and Production Engineering DIMNP, University o/Pisa, Largo Lazzarino, 2, Pisa, Italy;

    Department of Mechanical Nuclear and Production Engineering DIMNP, University o/Pisa, Largo Lazzarino, 2, Pisa, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ventilation; fuel cell; hydrogen distribution; experiments;