...
首页> 外文期刊>International journal of hydrogen energy >Turbulent diffusion flames of coal derived-hydrogen supplied low calorific value syngas mixtures in a new type of burner: An experimental study
【24h】

Turbulent diffusion flames of coal derived-hydrogen supplied low calorific value syngas mixtures in a new type of burner: An experimental study

机译:新型燃烧器中煤制氢提供的低热值合成气混合物的湍流扩散火焰:实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

This study is concerned with the turbulent diffusion flames of coal derived-hydrogen supplied low calorific value syngases in a new type of burner. In this new type of burner, hydrogen is supplied from the center of the burner to the flame zone in order to improve the combustion performances of these coal-derived syngases. Temperature and emission values have been experimentally performed on axial and radial directions by using thermocouples and a flue gas analyzer through the combustor. All experiments have been studied for a thermal power of 10 kW and an equivalence ratio of phi = 0.83. The coal-derived low calorific value syngases have been properly combusted using the new type of burner within the present study. The results show that the maximum temperature measurements of the generator and blast furnace gases without hydrogen supply were measured and determined to be 863.9 degrees C and 717.3 degrees C in the flame zone, respectively. The maximum flame temperatures of these syngases were also determined to be 965.9 degrees C for generator gas with hydrogen supply (2.5 kW), 1013.1 degrees C for generator gas with hydrogen supply (5 kW), 883.2 degrees C for blast-furnace gas with hydrogen supply (2.5 kW) and 898 degrees C for blast-furnace gas with hydrogen supply (5 kW), respectively. It can be concluded that the flame temperatures of these syngases increase as hydrogen is supplied to the flame zone as expected. It may also be said that the NOx levels of the generator and blast-furnace gases without hydrogen (3 ppm and 2 ppm in the flame region) are very low in comparison to that of the natural gas flame due to their low flame temperatures. However, it is found out that the NOx levels increase rapidly as hydrogen is supplied to the flame. These values were determined to be 85 ppm and 45 ppm under the generator gas and blast-furnace gas with hydrogen supplies (5 kW) combustion conditions. It can also be demonstrated that the presence of CO2 in the fuels (up to 8% by volume) leads to a high volume of CO2 emissions. (C) 2016 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
机译:这项研究与一种新型燃烧器中煤制氢提供的低热值合成气的湍流扩散火焰有关。在这种新型燃烧器中,从燃烧器的中心向火焰区供应氢气,以改善这些煤衍生的合成气的燃烧性能。通过使用热电偶和通过燃烧室的烟气分析仪,已经在轴向和径向方向上对温度和排放值进行了实验。所有实验均针对10 kW的热功率和phi = 0.83的当量比进行了研究。在本研究中,已使用新型燃烧器对源自煤的低热值合成气进行了适当燃烧。结果表明,在没有氢气供应的情况下,对发生器和高炉气体的最高温度测量值进行了测量,并确定在火焰区分别为863.9摄氏度和717.3摄氏度。还确定了这些合成气的最高火焰温度分别为:含氢气的发电气体(2.5千瓦)为965.9摄氏度,含氢气的发电气体(5千瓦)为1013.1摄氏度,含氢气的高炉煤气为883.2摄氏度分别使用氢气供应(5 kW)的高炉煤气(2.5 kW)和898摄氏度。可以得出结论,这些合成气的火焰温度会随着氢气按预期方式供应到火焰区域而增加。也可以说,与天然气火焰相比,不含氢的发生器和高炉气体的NOx水平(在火焰区域为3 ppm和2 ppm)非常低。然而,发现随着向火焰供应氢,NOx水平迅速增加。在具有氢气供应(5 kW)燃烧条件的发生器气体和高炉气体下,这些值确定为85 ppm和45 ppm。还可以证明燃料中存在二氧化碳(按体积计最多8%)会导致大量的二氧化碳排放。 (C)2016氢能出版物有限公司。由Elsevier Ltd.出版。保留所有权利。

著录项

  • 来源
    《International journal of hydrogen energy》 |2017年第4期|2411-2423|共13页
  • 作者

    Karyeyen Serhat; Ilbas Mustafa;

  • 作者单位

    Gazi Univ, Fac Technol, Dept Energy Syst Engn, TR-06500 Ankara, Turkey;

    Gazi Univ, Fac Technol, Dept Energy Syst Engn, TR-06500 Ankara, Turkey;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Burner; Emission; Hydrogen; Syngas;

    机译:燃烧器;排放物;氢;合成气;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号