首页> 外文期刊>International Journal of Heat and Mass Transfer >Enhanced food sterilization through inclination of the container walls and geometry modifications
【24h】

Enhanced food sterilization through inclination of the container walls and geometry modifications

机译:通过倾斜容器壁和修改几何形状来增强食品灭菌

获取原文
获取原文并翻译 | 示例
       

摘要

It is desirable to reduce the time taken for sterilization without compromising on the criterion of the slowest heating zone (SHZ) in the container reaching the minimum prescribed temperature. In this study, the required sterilization times for food cans of equal volumes but different shapes ranging from full cone through truncated cones to full cylinder were investigated. Further, the effect of orientation of the can was also investigated by inclining these geometries from 0-180°. The non-Newtonian fluid (0.85% w/w CMC) was taken as the test food material and its laminar flow behavior analysed using computational fluid dynamics. It was observed that among these geometries the lowest sterilization time was observed for a vertically oriented upright full conical can. The cylinder gave lower sterilization time when oriented horizontally than vertically. The sterilization times of truncated conical cans were intermediate to those determined for full cone and cylinder. Even a small inclination in the orientation of the cans may lead to significant increase in the sterilization times due to decrease in the convective velocities. The slowest heating zone movement in both axial and radial directions was tracked for various geometries and typical results are presented. The convective velocities, volume of region above and the surface area below the slowest heating zone determine the time taken for sterilization. When geometry modifications are made for aesthetic reasons to the food container, the utilization of known sterilization times for the conventional cylindrical can of the same volume may be inappropriate for suitable thermal treatment.
机译:期望在不损害容器中最慢加热区(SHZ)达到最低规定温度的标准的情况下减少灭菌时间。在这项研究中,研究了等体积但形状从完整圆锥体到截头圆锥体到完整圆柱体的食品罐所需的灭菌时间。此外,还通过将这些几何形状从0-180°倾斜来研究罐的定向效果。以非牛顿流体(0.85%w / w CMC)作为测试食品材料,并使用计算流体动力学分析其层流行为。观察到,在这些几何形状中,对于垂直定向的立式全锥形罐,观察到的杀菌时间最短。水平放置时,圆筒的灭菌时间要短于垂直放置。截锥形罐的灭菌时间比全锥和圆柱的灭菌时间要中等。由于对流速度的降低,即使罐子的取向即使很小的倾斜也可能导致灭菌时间的显着增加。跟踪了各种几何形状在轴向和径向上最慢的加热区运动,并给出了典型结果。对流速度,最慢加热区上方的区域体积和下方的表面积决定了灭菌所需的时间。当出于美学原因对食物容器进行几何形状修改时,对于相同体积的常规圆柱形罐使用已知的灭菌时间可能不适用于合适的热处理。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号