首页> 外文期刊>International Journal of Heat and Mass Transfer >Analysis of a novel combined heat exchange strategy applied for cooling towers
【24h】

Analysis of a novel combined heat exchange strategy applied for cooling towers

机译:一种新型混合热交换策略分析冷却塔

获取原文
获取原文并翻译 | 示例
           

摘要

Excessive heat transfer in cooling towers causes not only large evaporation loss, but also the diffusion of rain-fog that brings problems of bacterial diffusion and environmental pollution. A novel cooling tower employing a multi-unit combined heat exchange strategy and a novel plate-heat-exchanger-packing were proposed, which mainly realize the replacement of direct heat exchange with partition in a low-temperature environment, thereby reduce evaporation loss. The heat and mass transfer characteristic of the cooling tower is obtained under three kinds of arrangements during different seasons through the experiment. The results showed that the novel cooling tower has excellent water-saving performance, it is expected that the annual water saving can reach 21.5%. Most importantly, the ambient temperature is the key factor influencing the evaporation loss. Therefore, an effective heat exchange strategy is provided.
机译:冷却塔中的过热传递不仅引起较大的蒸发损失,还导致雨雾的扩散,从而带来细菌扩散和环境污染问题。提出了一种采用多单元组合热交换策略和新型板式热交换器包装的新型冷却塔,主要实现了在低温环境中与分区的直接热交换,从而降低蒸发损失。通过实验在不同季节的三种布置下获得冷却塔的热量和传质特性。结果表明,新型冷却塔具有优异的节水性能,预计每年节水可达到21.5%。最重要的是,环境温度是影响蒸发损失的关键因素。因此,提供了有效的热交换策略。

著录项

  • 来源
    《International Journal of Heat and Mass Transfer》 |2021年第4期|120910.1-120910.12|共12页
  • 作者单位

    School of Mechanical Engineering Changzhou University Changzhou China;

    School of Mechanical Engineering Changzhou University Changzhou China;

    School of Mechanical Engineering Changzhou University Changzhou China Jiangsu Key Laboratory of Green Process Equipment Changzhou University Changzhou China;

    School of Mechanical Engineering Changzhou University Changzhou China Jiangsu Seagull Cooling Tower Co. Ltd. China;

    Jiangsu Seagull Cooling Tower Co. Ltd. China;

    School of Mechanical Engineering Changzhou University Changzhou China Jiangsu Key Laboratory of Green Process Equipment Changzhou University Changzhou China;

    School of Mechanical Engineering Changzhou University Changzhou China Jiangsu Key Laboratory of Green Process Equipment Changzhou University Changzhou China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Cooling tower; Heat exchange strategy; Packing; Water saving;

    机译:冷却塔;热交换策略;包装;节水;