In this study, the condensation heat transfer characteristics of R245fa in a shell and plate heat exchanger (SPHE) are measured and analyzed by varying the mean vapor quality from 0.16 to 0.86, mass flux from 16.0 to 45.0 kg M-2 S-1, heat flux from 1.3 to 9.0 kW M-2, and saturation temperature from 90 to 120 degrees C for high-temperature heat pumps (HTHPs). The condensation heat transfer coefficient and frictional pressure drop are shown to increase with increasing mean vapor quality and mass flux and with decreasing saturation temperature. The condensation heat transfer coefficient of R245fa in SPHE is on average 5.9% lower than that in the brazed plate heat exchanger (BPHE) with a similar effective heat transfer area. However, the average two-phase frictional pressure drop of R245fa in SPHE is 16.7% lower than that in BPHE. Empirical correlations for the condensation heat transfer coefficient and two-phase frictional pressure drop in SPHE are developed with mean absolute errors of 8.2% and 9.4%, respectively. (C) 2018 Elsevier Ltd. All rights reserved.
机译:在这项研究中,通过将平均蒸气质量从0.16更改为0.86,将质量通量从16.0更改为45.0 kg M-2 S-1,来测量和分析R245fa在壳板式换热器(SPHE)中的冷凝传热特性。高温热泵(HTHP)的热通量从1.3到9.0 kW M-2,饱和温度从90到120摄氏度。结果表明,冷凝水的传热系数和摩擦压降随着平均蒸气质量和质量通量的增加以及饱和温度的降低而增加。 SPHE中R245fa的冷凝传热系数平均比有效传热面积相似的钎焊板式换热器(BPHE)低5.9%。但是,SPHE中R245fa的平均两相摩擦压降比BPHE中低16.7%。 SPHE中凝结传热系数和两相摩擦压降的经验相关性分别为8.2%和9.4%的平均绝对误差。 (C)2018 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号