首页> 外文期刊>International journal of environmental analytical chemistry >A novel method for the simultaneous determination of Pb (Ⅱ), Cd (Ⅱ) and Zn (Ⅱ) in environmental water samples
【24h】

A novel method for the simultaneous determination of Pb (Ⅱ), Cd (Ⅱ) and Zn (Ⅱ) in environmental water samples

机译:同时测定环境水样中铅(Cd),镉(Cd)和锌(Zn)的新方法

获取原文
获取原文并翻译 | 示例
       

摘要

A novel UV-VIS spectrophotometric method was developed in this study by using solid phase extraction procedure for the simultaneous preconcentration, separation and determination of trace levels of Pb (II), Cd (II) and Zn (II) ions in various water samples by using Amberlite N,N-bis(salicylidene)cyclohexanediamine (SCHD) resin. This study presents the results of experimental procedures carried out like the adsorption of analytes to the resin, influences of some analytical parameters that effect the recovery such as pH, sample volume, sample flow rate, eluent type and concentration, eluent volume, eluent flow rate and the effects of alkaline metals, earth alkaline metals and some other transition metals. The analytes in the samples with the adjusted pH range of 4-7 were adsorbed on XAD-4-SCHD resin and eluted by using 1.0 mol L-1 nitric acid. The amounts of ions were determined by using UV-VIS spectrometer. The limits of detection were 0.03, 0.07 and 0.05 mu g mL(-1) for Pb (II), Cd (II) and Zn (II), respectively. The accuracy of the method was assured by the analysis of the certified standard water sample NW-TMDA-70.2 and the observed recoveries were above 93%. Different environmental water samples that contain trace amounts of Pb (II), Cd (II) and Zn (II) were analysed by using the method developed in this study. Same samples were also analysed by ICP-MS for comparison and almost the similar results were observed. The method developed in this study was successfully applied to the various environmental water samples to determine the trace levels of Pb (II), Cd (II) and Zn (II) ions.
机译:本研究开发了一种新型的UV-VIS分光光度法,该方法采用固相萃取程序同时进行了预富集,分离和测定水中各种痕量Pb(II),Cd(II)和Zn(II)离子的痕量水平。使用Amberlite N,N-双(水杨基)环己二胺(SCHD)树脂。这项研究提供了实验程序的结果,例如分析物在树脂上的吸附,一些影响回收率的分析参数的影响,例如pH,样品量,样品流速,洗脱液类型和浓度,洗脱液体积,洗脱液流速以及碱金属,碱土金属和其他过渡金属的影响。 pH值调整为4-7的样品中的分析物吸附在XAD-4-SCHD树脂上,并使用1.0 mol L-1硝酸洗脱。通过使用UV-VIS光谱仪确定离子的量。铅(II),镉(II)和锌(II)的检出限分别为0.03、0.07和0.05μg mL(-1)。通过对认证的标准水样品NW-TMDA-70.2进行分析,可以确保该方法的准确性,并且观察到的回收率超过93%。使用本研究开发的方法分析了含有痕量Pb(II),Cd(II)和Zn(II)的不同环境水样品。还通过ICP-MS分析了相同的样品进行比较,并观察到几乎相似的结果。本研究开发的方法已成功应用于各种环境水样中,以测定痕量水平的Pb(II),Cd(II)和Zn(II)离子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号