首页> 外文期刊>International journal of environmental analytical chemistry >Electrochemical preconcentration of ultra-trace Cd~(2+) from environmental and biological samples prior to its determination using carbon paste electrode impregnated with ion imprinted polymer nanoparticles
【24h】

Electrochemical preconcentration of ultra-trace Cd~(2+) from environmental and biological samples prior to its determination using carbon paste electrode impregnated with ion imprinted polymer nanoparticles

机译:使用浸有离子印迹聚合物纳米颗粒的碳糊电极测定环境中和生物样品中的痕量Cd〜(2+)之前的电化学预浓缩

获取原文
获取原文并翻译 | 示例
       

摘要

Cadmium (Cd) is known as one of the most toxic elements among the heavy metals. This study proposes an electrochemical preconcentration method using the ion imprinted polymer nanoparticles modified carbon paste electrode (IIP-CPE) for the stripping voltammetry determination of Cd2+ in the environmental and biological samples. These IIP NPs were synthesised using ethylene glycol dimethacrylate as the cross-linker, 2,2MODIFIER LETTER PRIME-azobisisobutyronitrile as the free radical initiator and 4MODIFIER LETTER PRIME-(4-vinylphenyl)-2,2MODIFIER LETTER PRIME:6MODIFIER LETTER PRIME,2"-terpyridine as the Cd-binding ligand. The calibration plot was linear in the concentration range of 4-500 nM (R-2 = 0.9936) with a sensitivity of 918 mu A mu M-1 cm(-2). The LOD based on 3S(b)/m (where m is the slope of the calibration curve and S-b is the standard deviation for five blank measurements) was found to be 1.94 nM. The relative standard deviations (RSDs) for single-electrode repeatability and electrode-to-electrode reproducibility were 3.0% and 5.6% (n = 5), respectively. The accuracy of the current method was confirmed by the analysis of urine quality control material (QCM, Seronorm(TM) Trace Elements Urine, REF NO 201205, Norway) and spiked blood, rice and water samples. Recoveries were found to be above 95.0% for all samples, which confirms the good performance of the proposed voltammetry method.
机译:镉(Cd)是重金属中毒性最高的元素之一。这项研究提出了一种使用离子印迹聚合物纳米粒子修饰的碳糊电极(IIP-CPE)的电化学预富集方法,用于溶出伏安法测定环境和生物样品中的Cd2 +。这些IIP NP是使用乙二醇二甲基丙烯酸酯作为交联剂,2,2修饰剂字母PRIME-偶氮二异丁腈作为自由基引发剂和4MODIFIER LETTER PRIME-(4-vinylphenyl)-2,2MODIFIER LETTER PRIME:6MODIFIER LETME PRIME,2 “-三联吡啶作为Cd结合配体。校正图在4-500 nM(R-2 = 0.9936)的浓度范围内呈线性,灵敏度为918μAμM-1 cm(-2)。基于3S(b)/ m(其中m是校准曲线的斜率,Sb是五次空白测量的标准偏差)的结果为1.94 nM。单电极重复性和电极的相对标准偏差(RSD)电极的重现性分别为3.0%和5.6%(n = 5),通过尿液质量控制材料(QCM,SeronormTM微量元素尿液,REF NO 201205,挪威)以及加标的血液,大米和水样本,回收率高于95.0%所有样品,证实了所提出的伏安法的良好性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号