首页> 外文期刊>International journal of environmental analytical chemistry >Eddy-covariance flux measurements in an Italian deciduous forest using PTR-ToF-MS, PTR-QMS and FIS
【24h】

Eddy-covariance flux measurements in an Italian deciduous forest using PTR-ToF-MS, PTR-QMS and FIS

机译:使用PTR-ToF-MS,PTR-QMS和FIS在意大利落叶林中进行涡流协方差通量测量

获取原文
获取原文并翻译 | 示例
       

摘要

A field campaign in a deciduous forest in Ispra, Italy, was performed by the Joint Research Centre, Ispra, Italy, together with University of Innsbruck, Austria, in 2013, using PTR-ToF-MS (proton transfer reaction - time-of-flight - mass spectrometry), PTR-QMS (proton transfer reaction - quadrupole mass spectrometry), FIS (fast isoprene sensor) and other instrumentations. The main purpose of the campaign was to measure volatile organic carbon (VOC). One of the outcomes of this investigation was the comparison between the three VOC measurement techniques, focusing on the VOC-flux values that could be measured, VOC-volume-mixing-ratio (VOC-VMR) values that could be measured, the number of VOCs identified/measured, and finally if any oxidation products from the primary emitted VOC could be identified/measured. To the best of our knowledge, it is the first time that these three techniques have been used simultaneously during a campaign in a forest, and the comparison of the three techniques is presented in details (PTR-ToF-MS, PTR-QMS and FIS). It was concluded that the isoprene data generated by the three instruments were in good agreement. With PTR-ToF-MS, the following main results were achieved during the summer campaign 2013: The VMR of isoprene was measured up to 16 ppb; large fluxes of isoprene with values up to 53nmolm(-2)s(-1) by PTR-ToF-MS; mean diurnal (24 h) averages of VMR of isoprene of (1.07 +/- 0.53) ppb and mean diurnal (24 h) flux of isoprene of (5.20 +/- 2.42)nmolm(-2)s(-1). For the isoprene oxidation products methyl-vinyl-ketone/methacrolein (MVK/MACR), VMRs of (0.42 +/- 0.22) ppb were measured as a mean diurnal (24 h) average. Mean diurnal (24 h) flux of MVK/MACR were measured to be (0.06 +/- 0.04)nmolm(-2)s(-1); for the monoterpenes, the VMR was measured to be (0.10 +/- 0.09) ppb mean diurnal (24 h) and mean diurnal (24 h) flux of monoterpenes to be (0.08 +/- 0.05)nmolm(-2)s(-1). Detailed descriptions of the fluxes/VMRs of other VOCs, acetone/methanol/acetaldehyde, are also presented. The results obtained here have also been compared to several other similar studies and campaigns.
机译:2013年,意大利伊斯普拉联合研究中心与奥地利因斯布鲁克大学联合研究中心利用PTR-ToF-MS(质子转移反应-时间-飞行-质谱),PTR-QMS(质子转移反应-四极质谱),FIS(快速异戊二烯传感器)和其他仪器。这项运动的主要目的是测量挥发性有机碳(VOC)。这项调查的结果之一是比较了三种VOC测量技术,重点是可以测量的VOC通量值,可以测量的VOC体积混合比(VOC-VMR)值,确定/测量了VOC,最后确定/测量了来自主要排放VOC的任何氧化产物。据我们所知,这是第一次在森林中的战役中同时使用这三种技术,并且详细介绍了这三种技术的比较(PTR-ToF-MS,PTR-QMS和FIS) )。结论是,三种仪器生成的异戊二烯数据非常吻合。使用PTR-ToF-MS,在2013年夏季运动中取得了以下主要成果:异戊二烯的VMR值高达16 ppb;通过PTR-ToF-MS获得的异戊二烯通量高达53nmolm(-2)s(-1);异戊二烯的VMR平均每日(24 h)平均值(1.07 +/- 0.53)ppb和异戊二烯的平均每日(24 h)通量(5.20 +/- 2.42)nmolm(-2)s(-1)。对于异戊二烯氧化产物甲基-乙烯基酮/甲基丙烯醛(MVK / MACR),VMR为(0.42 +/- 0.22)ppb的平均每日(24 h)平均测量值。 MVK / MACR的平均每日(24 h)通量测得为(0.06 +/- 0.04)nmolm(-2)s(-1);对于单萜,测得的VMR为(0.10 +/- 0.09)ppb平均日流量(24 h)和平均日流量(24 h)的单萜流量为(0.08 +/- 0.05)nmolm(-2)s( -1)。还介绍了其他VOC(丙酮/甲醇/乙醛)的通量/ VMR的详细说明。这里获得的结果也已经与其他几个类似的研究和活动进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号