A novel on-line flow injection solid phase extraction method for the preconcentration of trace toxic metals prior determination by flame atomic absorption spectrometry (FI-SPE-FAAS) was developed. The potential application of the hydrophobic reversed phase co-polymer sorbent Strata(TM)-X packed into an on-line microcolumn for the quantification of Cd(II), Pb(II), Cu(II) and Cr(VI) was demonstrated for the first time. The method was based on the on-line formation of metal complexes using sodium diethyl-dithiocarbamate (DDTC) and on the subsequent retention of them onto the sorbent material. The target analytes were completely eluted by methanol and, subsequently, directed to FAAS for quantification. All chemical and flow variables affecting the performance of the developed method were thoroughly studied and optimised. For a preconcentration time of 90s and a sampling frequency of 28h(-1), enhancement factors of 72, 140, 185, 63 and detection limits of 0.18, 1.6, 0.20 and 1.2 g L (-1) were obtained for Cd(II), Pb(II), Cu(II) and Cr(VI), respectively. The accuracy of the FI-SPE-FAAS method was evaluated by analysing certified reference materials as well as spiked environmental water samples. Furthermore, a comparative study of the analytical characteristics, the properties as well as the chemical structures of commercial polymeric based sorbent materials was employed. Strata-X sorbent was compared against Hypersep(TM) SCX, Bond Elut (R) Plexa(TM) PCX, Oasis-HLBTM and Nobias(TM) PA-1, regarding the adaptation in on-line FI-SPE-FAAS systems for metal determination, and herein presented.
机译:建立了一种在线富集固相萃取-火焰原子吸收光谱法(FI-SPE-FAAS)测定痕量有毒金属的新方法。疏水反相共聚物吸附剂StrataTM-X装在在线微柱中用于定量Cd(II),Pb(II),Cu(II)和Cr(VI)的潜在应用得到了证明首次。该方法基于使用二乙基-二硫代氨基甲酸钠(DDTC)在线形成金属络合物以及随后将其保留在吸附剂材料上的方法。目标分析物被甲醇完全洗脱,然后直接送至FAAS进行定量。彻底研究和优化了影响开发方法性能的所有化学和流量变量。对于90s的预浓缩时间和28h(-1)的采样频率,Cd(II)的增强因子为72、140、185、63,检出限为0.18、1.6、0.20和1.2 g L(-1)。 ),Pb(II),Cu(II)和Cr(VI)。通过分析经认证的参考物质以及加标的环境水样品,评估了FI-SPE-FAAS方法的准确性。此外,对商业聚合物基吸附剂材料的分析特性,性能以及化学结构进行了比较研究。比较了Strata-X吸附剂与Hypersep TM SCX,Bond Elut Plexa TM PCX,Oasis-HLBTM和Nobias TM PA-1在在线FI-SPE-FAAS系统中的适应性。金属测定,在此介绍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号