摘要

Heat transfer, friction factor and enhancement efficiency characteristics in a circular tube fitted with conical-ring turbulators and a twisted-tape swirl generator have been investigated experimentally. The heat transfer test section is heated electrically imposing axially and circumferentially constant wall heat flux boundary conditions. In the experiments, two enhancement heat transfer devices are applied. One is the conical-ring used as a tabulator and placed in the tested tube and the other is the twisted-tape swirl generator placed at the core of the conical-ring. Air as the tested fluid is passed both enhancement devices in a Reynolds number range of 6000 to 26,000. Two twisted-tapes of different twist ratios, Y=3.75, and 7.5, are introduced in each run. The experimental results reveal that the tube fitted with the conical-ring and twisted-tape provides Nusselt number values of around 4 to 10% and enhancement efficiency of 4 to 8% higher than that with the conical-ring alone. A maximum heat transfer rate of 367% and enhancement efficiency of around 1.96 is found for using the conical-ring and the twisted-tape of Y=3.75. For all the devices used, the enhancement efficiency tends to decrease with the rise of Reynolds number and to be nearly uniform for Reynolds number over 16,000. In addition, correlations for Nusselt number, friction factor and performance evaluation criteria to assess the real benefits in using the tabulator and swirl generator of the enhanced tube are determined.
机译:实验研究了装有圆锥环湍流器和扭曲带旋流发生器的圆管中的传热,摩擦系数和增强效率特性。对传热测试段进行电加热,以施加轴向和周向恒定的壁热通量边界条件。在实验中,应用了两个增强传热装置。一个是用作制表器的圆锥形环,放置在测试管中,另一个是放置在圆锥形环芯处的扭带涡旋发生器。作为测试流体的空气通过了两个雷诺数范围为6000至26,000的增强装置。每次运行中引入了两种不同扭曲比的扭曲带,分别为Y = 3.75和7.5。实验结果表明,与仅使用圆锥形环的管相比,装有圆锥形环和扭曲带的管的Nusselt值大约为4%至10%,增强效率提高了4%至8%。使用Y = 3.75的圆锥形环和扭曲带,发现最大传热率达到367%,增强效率约为1.96。对于所有使用的器件,增强效率趋于随雷诺数的增加而降低,而对于超过16,000的雷诺数则几乎是均匀的。此外,还确定了努塞尔数,摩擦因数和性能评估标准之间的相关性,以评估使用增强管的制表机和涡旋发生器的实际好处。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号