首页> 外文期刊>Instrumentation and Measurement, IEEE Transactions on >A High-Resolution PXI Digitizer for a Low-Value-Resistor Calibration System
【24h】

A High-Resolution PXI Digitizer for a Low-Value-Resistor Calibration System

机译:用于低值电阻校准系统的高分辨率PXI数字化仪

获取原文
获取原文并翻译 | 示例
       

摘要

This paper characterizes the metrological properties of a dual-channel high-resolution digitizer designed for use in a system to calibrate standard resistors with values between 1 $hbox{m} Omega$ and 10 $Omega$ at frequencies from 40 Hz to 10 kHz. The possibility of using a digitizer to measure the complex voltage ratio is analyzed for both digitizer operating modes: the dual-channel mode with a simultaneous sampling and the single-channel mode with a sequential sampling in which an additional external multiplexer is used. The method of acquiring samples presented in this paper was used to investigate and compare the short-time stability and temperature influences on the metrological properties of the digitizer. This makes it possible to reduce the influence of the instability of the generator, being the signal source for the tested digitizer, on the research results. Moreover, presented in this paper are the frequency characteristics of the magnitude and phase of the complex voltage ratio, as well as the research results of the digitizer linearity and the phase measurement accuracy. All measurements discussed here were performed for both digitizer operating modes.
机译:本文描述了一种双通道高分辨率数字化仪的计量学特性,该数字化仪设计用于在系统中校准值在1 $ hbox {m}之间的标准电阻器。 Omega $ 和10个 $ Omega $ ,频率为40 Hz至10 kHz。对于两种数字化仪工作模式,都分析了使用数字化仪测量复数电压比的可能性:具有同时采样的双通道模式和具有顺序采样的单通道模式,其中使用了额外的外部多路复用器。本文提出的样品获取方法用于调查和比较短期稳定性和温度对数字化仪计量性能的影响。这使得有可能减少作为被测数字转换器信号源的发生器的不稳定性对研究结果的影响。此外,本文介绍了复电压比的幅度和相位的频率特性,以及数字化仪线性度和相位测量精度的研究结果。此处讨论的所有测量均针对两种数字化仪操作模式执行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号