The objective of this paper is to estimate the sample size required to assess the maximum pit size over an entire asset that is subject to pitting corrosion. The Bayesian updating approach and the extreme value method are integrated into a single proposed framework to estimate the sample size. The extreme value method is used to predict the maximum pit size by extrapolating the inspected area (sample) to the entire asset's area. The Bayesian updating approach is used to update prior information obtained from the previous inspection once newly obtained information is available from the current inspection. The estimated sample size ensures that the predicted maximum pit size over the entire asset is within an acceptable margin of error at a specified confidence level. Using the proposed framework, two closed-form formulae are developed for calculating the sample size required to assess pitting corrosion. The two formulae address the two situations when prior information is either available or unavailable. These formulae are compared to the classical method for calculating the sample size through a case study of a pipeline subject to pitting corrosion. The comparison shows that the sample size estimated with the classical method is not large enough to assess the maximum pit size over the entire pipeline.
机译:本文的目的是估计样本数量,以评估遭受点蚀腐蚀的整个资产的最大点蚀尺寸。贝叶斯更新方法和极值方法被集成到一个建议的框架中以估计样本量。极值方法用于通过将检查区域(样本)外推到整个资产区域来预测最大矿坑大小。一旦从当前检查获得新获得的信息,则使用贝叶斯更新方法来更新从先前检查获得的先前信息。估计的样本数量可确保在指定的置信度下,整个资产的预计最大坑尺寸在可接受的误差范围内。使用提出的框架,开发了两个封闭形式的公式,用于计算评估点蚀所需的样本量。当现有信息可用或不可用时,这两个公式可解决两种情况。通过对遭受点蚀腐蚀的管道进行案例研究,将这些公式与用于计算样本量的经典方法进行了比较。比较结果表明,用经典方法估算的样本量不足以评估整个管道上的最大凹坑尺寸。

著录项

  • 来源
    《Insight》 |2013年第6期|290-296|共7页
  • 作者

    M Khalifa; F Khan; M Haddara;

  • 作者单位

    Faculty of Engineering & Applied Science, Memorial University, St John's, NL, A1B 3X5, Canada;

    Faculty of Engineering & Applied Science, Memorial University, St John's, NL, A1B 3X5, Canada;

    Faculty of Engineering & Applied Science, Memorial University, St John's, NL, A1B 3X5, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Sample size; pitting corrosion; extreme value method; Bayesian approach; inspection interval;