When a single line to ground fault (SLGF) happens on the MV side of an HV/MV system, only a small portion of the fault current is injected into the ground by the ground grid of the faulty substation. In fact, the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing, this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real SLGF was made and fault currents were measured in the faulty substation and in four neighboring substations. In this paper, the problem of fault current distribution is introduced, the test system is described and the measurements results are presented.
机译:当在HV / MV系统的MV侧发生单线接地故障(SLGF)时,故障变电站的接地网只会将一小部分故障电流注入地面。实际上,故障电流分布在接地电极和中压电缆护套之间。在中性线隔离或谐振接地的系统中,这足以提供抗电击的安全性。在真实的MV配电网络上进行了实验测量:制作了真实的SLGF,并在故障变电站和四个相邻变电站中测量了故障电流。本文介绍了故障电流分布的问题,描述了测试系统并给出了测量结果。