Constant on-time control has been widely used for power supply controllers in industry due to its fast transient response. However, existing stability analysis in literatures can only explain conditions with single type of output capacitor and usually recommend high equivalent series resistance $( hbox{ESR}) ast {C}_{o}$ for stable operation. This paper proposes a new stability analysis for constant on-time control with combined output capacitors, which are often used in practical applications. Based on time-domain analysis for the inductor current, the output voltage, and the output capacitor currents, it is revealed that higher ESR and higher capacitance values can deteriorate the stability in many conditions with combined output capacitors. Also, a simple loop compensation solution is provided to improve stability. Simulation and experimental results demonstrate the theoretical analysis.
机译:由于其快速的瞬态响应,恒定导通时间控制已在工业中广泛用于电源控制器。但是,文献中现有的稳定性分析只能用一种类型的输出电容器来解释情况,并且通常建议使用高等效串联电阻。<{Formula Formulatype =“ inline”> $(hbox {ESR})ast {C } _ {o} $ 稳定运行。本文提出了一种用于组合输出电容器的恒定导通时间控制的新稳定性分析方法,该方法经常在实际应用中使用。根据对电感器电流,输出电压和输出电容器电流的时域分析,可以发现,在组合有输出电容器的许多条件下,较高的ESR和较高的电容值可能会降低稳定性。而且,提供了一种简单的环路补偿解决方案来提高稳定性。仿真和实验结果证明了理论分析。