This paper investigates the problem of multiple distributed generator (DG units) placement to achieve a high loss reduction in large-scale primary distribution networks. An improved analytical (IA) method is proposed in this paper. This method is based on IA expressions to calculate the optimal size of four different DG types and a methodology to identify the best location for DG allocation. A technique to get the optimal power factor is presented for DG capable of delivering real and reactive power. Moreover, loss sensitivity factor (LSF) and exhaustive load flow (ELF) methods are also introduced. IA method was tested and validated on three distribution test systems with varying sizes and complexity. Results show that IA method is effective as compared with LSF and ELF solutions. Some interesting results are also discussed in this paper.
机译:本文研究了在大型一次配电网中实现高损耗减少的多个分布式发电机(DG单元)布置问题。本文提出了一种改进的分析方法。该方法基于IA表达式来计算四种不同DG类型的最佳大小,以及一种用于确定DG分配的最佳位置的方法。针对能够提供有功和无功功率的DG,提出了一种获得最佳功率因数的技术。此外,还介绍了损耗敏感因子(LSF)和穷竭潮流(ELF)方法。 IA方法已在三个具有不同大小和复杂性的分布测试系统上进行了测试和验证。结果表明,与LSF和ELF解决方案相比,IA方法是有效的。本文还讨论了一些有趣的结果。