首页> 外文期刊>電子情報通信学会技術研究報告 >高時間分解能を実現するSETパルス幅測定回路の提案
【24h】

高時間分解能を実現するSETパルス幅測定回路の提案

机译:SET脉冲宽度测量电路实现高时间分辨率的建议

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents two circuits to measure pulse width distribution of single event transients (SETs). We first review requirements for SET measurement in accelerated neutron radiation test and point out problems of previous works, in terms of time resolution, time/area efficiency for obtaining large samples and certainty in absolute values of pulse width. We then devise two measurement circuits and a pulse generator circuit that satisfy all the requirements and attain sub--FO1-inverter-delay resolution, and propose a measurement procedure for assuring the absolute width values. Operation of one of the proposed circuits was confirmed by a radiation experiment of alpha particles with a fabricated test chip.%本稿では,放射線起因一過性パルス(SET)のパルス幅測定回路を提案する.まず中性子加速実験によるSET測定に必要な要件を検討し,時間分解能,測定効率,パルス幅の絶対値の正確さ,などの点から従来手法の問題点を指摘する.さらに,SET測定回路に求められる全ての要件を満たし,フアンアウト1インバータ遅延より細かい時間分解能を実現する,2種類の測定回路と校正用パルスジェネレータを提案する.提案測定回路のうち,1種類の測定回路と校正用パルスジェネレータを搭載した65nmテストチップでα線照射実験を行い,提案回路の有効性を確認した.
机译:本文介绍了两种用于测量单事件瞬变(SET)脉冲宽度分布的电路,我们首先回顾加速中子辐射测试中SET测量的要求,并指出从时间分辨率,时间/面积效率等方面进行工作的问题。然后,我们设计两个测量电路和一个脉冲发生器电路,这些电路可以满足所有要求并获得低于FO1的逆变器延迟分辨率,并提出一种测量程序以确保绝对宽度值。拟议的电路之一的运行已通过用制造的测试芯片对α粒子进行的辐射实验得以证实。%在本文中,我们提出了一种用于辐射诱发的瞬态脉冲(SET)的脉冲宽度测量电路。我们检查了SET测量的要求,并指出了传统方法在时间分辨率,测量效率,脉宽绝对值的准确性等方面的问题。此外,我们还展示了SET测量电路的所有要求。我们提出了两种类型的测量电路和一个校准脉冲发生器,它们可以满足要求,并实现比扇出1逆变器延迟更好的时间分辨率。我们在芯片上进行了α射线辐照实验,并证实了该电路的有效性。