首页> 外文期刊>電気学会論文誌 B:電力·エネルギー部門誌 >光CTの波長分割多重伝送技術を用いたケーブル事故区間検出装置の開発
【24h】

光CTの波長分割多重伝送技術を用いたケーブル事故区間検出装置の開発

机译:利用光学CT的波分复用传输技术开发电缆故障断面检测装置

获取原文
获取原文并翻译 | 示例
           

摘要

A fault detection system is applied to power lines consisting of both overhead power line and underground power cable in order to detect a fault on the underground power cable section and prevent the automatic reclosing.rnThe fault detection system using optical fiber current sensor has two subjects. The fist subject is that we have to use wound-type current transformer together, when applying the fault detection system to single-core underground power cable. The second subject is that we are not able to detect three-phase short-circuit fault in using the fault detection system.rnThis paper describes that we developed a new fault detection system using optical fiber current sensor by applying the multiplex transmission technology of optical fiber current sensor signal in order to solve these subjects.%ケーブル事故区間検出装置(以下,事故検)は,架空送rn電線と地中ケーブルが混在する送電線において,地中ケーrnブル区間の事故を検出し,再閉路による設備損壊の拡大やrnOFケーブルの火災を阻止するものである。rn我々は,従来のアナログ形事故検が中和トランス等の製rn造?補修が困難となったことから,平成16年に光ファイrnバ電流センサを用いた事故検(以下,光事故検)を開発しrnた。
机译:为了在地下电力电缆部分中检测出故障并防止自动重合闸,将故障检测系统应用于由架空电力线和地下电力电缆组成的电力线上。使用光纤电流传感器的故障检测系统具有两个主题。第一个主题是,将故障检测系统应用于单芯地下电力电缆时,我们必须同时使用绕线型电流互感器。第二个问题是使用故障检测系统无法检测到三相短路故障。rn本文介绍了我们通过应用光纤的多路传输技术开发了一种使用光纤电流传感器的新型故障检测系统。为了解决这些问题,请使用当前的传感器信号。%ケーブル事故区间検出装置(以下,事故検)は,架空送电线,我再,従来のアナログ形事故検が中和トランス等の制rn造?补修が困难となったことから,平成16年に光ファイrnバ电流センサを用いた事故検(以下,光事故検)を开をrnた。