首页> 外文期刊>Power Electronics, IEEE Transactions on >Evaluation of Iron Loss of AC Filter Inductor Used in Three-Phase PWM Inverters Based on an Iron Loss Analyzer
【24h】

Evaluation of Iron Loss of AC Filter Inductor Used in Three-Phase PWM Inverters Based on an Iron Loss Analyzer

机译:基于铁损分析仪的三相PWM逆变器交流滤波器电感铁损评估

获取原文
获取原文并翻译 | 示例
       

摘要

The authors have proposed two methods for iron loss evaluation of the ac filter inductor used in a pulsewidth modulation (PWM) inverter. The first method is a loss map method, which can be used for the iron loss calculation of the ac filter inductor without using a real PWM inverter, and the second method is an iron loss analyzer (ILA), which can measure the iron loss of the ac filter inductor during every switching period on a real PWM inverter. In this paper, the measurement results obtained using the ILA and the results calculated using the loss map method on both the single-phase and three-phase inverters are compared. The calculated iron loss of the ac filter inductor on the three-phase PWM inverter is found to have a relatively large error for certain PWM pulse conditions. In order to reduce the calculation error, the authors propose a modified loss calculation method and demonstrate that the calculation error is reduced to less than 2%.
机译:作者提出了两种方法来评估脉宽调制(PWM)逆变器中使用的交流滤波电感器的铁损。第一种方法是损耗图方法,可用于计算交流滤波电感器的铁损,而无需使用实际的PWM逆变器;第二种方法是铁损分析器(ILA),可测量铁损的铁损。实际PWM逆变器上的每个开关周期内的交流滤波器电感。在本文中,比较了使用ILA获得的测量结果和使用损耗图法计算的单相和三相逆变器的结果。对于某些PWM脉冲条件,发现在三相PWM逆变器上计算出的交流滤波电感器的铁损具有相对较大的误差。为了减少计算误差,作者提出了一种改进的损耗计算方法,并证明了将计算误差减小到小于2%。