首页> 外文期刊>IEEE Transactions on Magnetics >Gap measurement in Nb/NbO/sub x//Al injection controlled planar three terminal devices
【24h】

Gap measurement in Nb/NbO/sub x//Al injection controlled planar three terminal devices

机译:Nb / NbO / sub x // Al注入控制平面三端子设备中的间隙测量

获取原文
获取原文并翻译 | 示例
       

摘要

The characteristics of Nb/NbO/sub x//Al injection-controlled planar three-terminal superconducting devices (injection-controlled links) have been studied experimentally. A built-in Nb/AlO/sub x//Nb Josephson junction is used to perform direct tunneling measurement, whose results show that the gap in the Nb strip decreases as its critical current is suppressed. It is also shown that the static characteristics of the devices with high and low injector resistance can be fitted to a simple heating model and a modified heating model, respectively.
机译:实验研究了Nb / NbO / sub x // Al注入控制平面三端子超导器件(注入控制连接)的特性。使用内置的Nb / AlO / sub x // Nb Josephson结进行直接隧穿测量,其结果表明,随着Nb临界电流的减小,Nb带中的间隙减小。还显示出具有高和低喷射器电阻的装置的静态特性可以分别拟合为简单的加热模型和修改的加热模型。