首页> 外文期刊>IEEE Transactions on Geoscience and Remote Sensing. >Stabilization of the Brightness Temperature of a Calibration Warm Load for Spaceborne Microwave Radiometers
【24h】

Stabilization of the Brightness Temperature of a Calibration Warm Load for Spaceborne Microwave Radiometers

机译:星载微波辐射计标定热负荷的亮温稳定

获取原文
获取原文并翻译 | 示例

摘要

We present the results of a study that shows that a simple design modification is sufficient to avoid a major shortcoming in the layout of external warm loads commonly used in the calibration of spaceborne microwave radiometers. The modification consists of placing a layer of Plastazote, a polyethylene foam, over the opening of the warm load enclosure. The foam is transparent at micrometer and millimeter wavelengths, is opaque in the infrared and visible, and isolates the warm load from the environment, keeping the temperature of the radiometric warm load constant. The proposed solution can be easily implemented and is suitable even for retrofitting on instruments that have already been built but not yet launched, and the material presents no obvious shortcomings that could prevent its intended application in space.
机译:我们提供的一项研究结果表明,简单的设计修改足以避免在星载微波辐射计的校准中常用的外部热负荷布局中出现重大缺陷。修改包括在热负荷外壳的开口上方放置一层Plastazote(一种聚乙烯泡沫)。泡沫在微米和毫米波长处是透明的,在红外线中是不透明的,并且是可见的,并且将热负荷与环境隔离,从而使辐射热负荷的温度保持恒定。所提出的解决方案可以轻松实施,甚至适用于对已建成但尚未启动的仪器进行改装,并且该材料没有明显的缺点,无法阻止其在太空中的预期应用。