首页> 外文期刊>IEEE Journal of Quantum Electronics >Accurate gas diagnostics for sealed-off CO/sub 2/ lasers using near-infrared DFB semiconductor lasers
【24h】

Accurate gas diagnostics for sealed-off CO/sub 2/ lasers using near-infrared DFB semiconductor lasers

机译:使用近红外DFB半导体激光器对封闭式CO / sub 2 /激光器进行准确的气体诊断

获取原文
获取原文并翻译 | 示例
       

摘要

The selective spectroscopic detection of CO/sub 2/ and H/sub 2/O in the gas mixture of a 400-W sealed-off CO/sub 2/ slab laser is reported. The detection is based on the acquisition of absorption Voigt profiles of two vibrational overtone transitions of CO/sub 2/ and H/sub 2/O, obtained using two InGaAsP distributed feedback (DFB) semiconductor lasers. This spectroscopic method enables a direct absolute measurement of the temporal evolution for the concentrations inside the laser active volume. Monitoring takes place during laser operation without gas extraction. The experiments carried out on CO/sub 2/ and H/sub 2/O abundances confirm the paramount importance of wall desorbance phenomena in all-metal radio frequency (RF) excited lasers.
机译:报道了选择性光谱检测400 W密封CO / sub 2 /平板激光器的气体混合物中CO / sub 2 /和H / sub 2 / O的情况。该检测基于对使用两个InGaAsP分布式反馈(DFB)半导体激光器获得的CO / sub 2 /和H / sub 2 / O的两个振动泛音跃迁的吸收Voigt轮廓的获取。这种光谱方法可以直接绝对测量激光有效体积内浓度的时间演变。监视在激光操作过程中进行,无需抽气。在CO / sub 2 /和H / sub 2 / O丰度上进行的实验证实了全金属射频(RF)激发激光器中壁脱附现象的最重要意义。