首页> 外文期刊>IEEE Journal of Quantum Electronics >Performance of Ar+-milled Ti:sapphire rib waveguides as single transverse-mode broadband fluorescence sources
【24h】

Performance of Ar+-milled Ti:sapphire rib waveguides as single transverse-mode broadband fluorescence sources

机译:Ar +铣削的Ti:蓝宝石肋形波导作为单横模宽带荧光源的性能

获取原文
获取原文并翻译 | 示例
       

摘要

Rib waveguides have been fabricated in pulsed-laser-deposited Ti:sapphire layers using photolithographic patterning and subsequent Ar+-beam milling. Fluorescence output powers up to 300 ΜW have been observed from the ribs following excitation by a 3-W multiline argon laser. Mode intensity profiles show high optical confinement and the measured beam propagation factors Mx2 and My2 of 1.12 and 1.16, respectively, indicate single transverse-mode fluorescence emission. Loss measurements using the self-pumped phase conjugation technique have yielded comparable values (1.7 dB/cm) for the ribs and the unstructured planar waveguide counterparts. The combination of optimum modal properties and strong optical confinement, together with sufficient levels of fluorescence output, make the single-moded Ti:sapphire rib waveguides a very interesting candidate as a fluorescence source for optical coherence tomography applications.
机译:肋波导已通过光刻图案化和随后的Ar +束铣削加工在脉冲激光沉积的Ti:蓝宝石层中制造。在3W多线氩激光激发后,从肋骨观察到高达300 MW的荧光输出功率。模式强度分布图显示出较高的光学限制,并且测得的光束传播因子Mx2和My2分别为1.12和1.16,表示单个横向模式荧光发射。使用自泵浦相位共轭技术进行的损耗测量得出了肋骨和非结构化平面波导对应物的可比较值(1.7 dB / cm)。最佳的模态特性和强大的光学限制以及足够水平的荧光输出相结合,使单模Ti:蓝宝石肋形波导成为光学相干断层扫描应用的荧光源,非常有趣。