The differences between the voltage outputs of Zener-diode based electronic voltage standards (Zeners) and standard cells, between Zeners and a Josephson array voltage standard (JAVS) and between pairs of Zeners are measured. The data are analysed as time series. They are serially correlated so that the use of the usual expression for the standard deviation of the mean, the experimental standard deviation divided by the square root of the number of measurements, to characterise the dispersion is not justified. Noise in Zeners is of a 1/f'nature and is characterised by using the power spectral density and Allan variance, a statistic used in time and frequency metrology. The uncertainty in the measurements of the l0V outputs of l3 Zeners is limited by l/f' noise to a 'floor' value ranging between two parts in l0~9 and eight parts in 10~9 of the nominal output value. Methods are proposed for estimating the Allan variance of a Zener using either a standard cell, a JAVS, or a small group of sbolar Zeners.
机译:测量基于齐纳二极管的电子电压标准(Zeners)和标准单元之间的电压输出,齐纳和约瑟夫森阵列电压标准(JAVS)之间以及齐纳对之间的电压差。数据按时间序列进行分析。它们是连续相关的,因此没有理由使用通常的平均值表示标准偏差,实验标准偏差除以测量次数的平方根来表征色散。齐纳二极管中的噪声具有1 / f性质,其特征在于使用功率谱密度和艾伦方差,即时间和频率计量学中使用的统计数据。 l3齐纳二极管的10V输出的测量不确定性受到l / f'噪声的限制,其“底”值介于标称输出值的10〜9的两个部分和10〜9的八个部分之间。提出了使用标准单元格,JAVS或一小部分支持者的齐纳二极管来估算齐纳二极管的Allan方差的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号