首页> 外文期刊>GWF >Tertiary Filtration with Ultrafiltration Membranes in Municipal Wastewater Treatment Plants
【24h】

Tertiary Filtration with Ultrafiltration Membranes in Municipal Wastewater Treatment Plants

机译:城市污水处理厂的超滤膜三次过滤

获取原文
获取原文并翻译 | 示例
           

摘要

During the operation of tertiary filtration stages in a dead-end-mode, retentate concentrate and rinsing water from membrane cleaning accrue naturally. Work on process solutions for these process waters with no additional particle loads for the tertiary membrane filtration stage and no further hydraulic loads is obviously necessary. A process engineering concept for the treatment of retentate volume flows by a combination of flotation technology, secondary filtration and centrifuge technology allows for a hydraulic isolation of the tertiary membrane filtration stage from the biological wastewater treatment.
机译:在三级过滤阶段以死胡同模式运行时,自然会积聚浓缩液和膜清洁液中的冲洗水。这些工艺用水的工艺解决方案无需三级膜过滤阶段的额外颗粒负荷,而且显然无需进一步的液压负荷。通过浮选技术,二次过滤和离心技术相结合的处理截留物流量的工艺工程概念,可以将三级膜过滤阶段与生物废水处理进行水力隔离。