首页> 外文期刊>Geothermics >Improving the performance of the down-hole heat exchanger at the Alpine Motel, Rotorua, New Zealand
【24h】

Improving the performance of the down-hole heat exchanger at the Alpine Motel, Rotorua, New Zealand

机译:改善新西兰罗托鲁阿高山汽车旅馆的井下热交换器的性能

获取原文
获取原文并翻译 | 示例
       

摘要

The township of Rotorua is situated on top of a shallow geothermal reservoir. The resource is easily accessible and is commonly used for district heating. Excessive exploitation in the 1970s and 1980s resulted in the decline of the unique thermal natural features in the Whakarewarewa geysers area, which prompted the government to set a production moratorium within a 1.5 km area around the geysers. The production wells at the Alpine Motel had to be abandoned in 1987 and the motel resorted to gas fired heaters. A down-hole heat exchanger (DHE) was used to supply the required heat, but only 22% of the heat demand was produced. Air lifting was implemented to improve the performance of the DHE, which resulted in a 125% increase in heat output. This significant increase in heat output compared to early trials was discussed. Recommendations are given to further improve the DHE performance.
机译:罗托鲁瓦(Rotorua)镇位于一个浅层地热库的顶部。该资源易于获取,通常用于区域供热。 1970年代和1980年代的过度开采导致了Whakarewarewa间歇泉地区独特的热自然特征的下降,这促使政府在间歇泉周围1.5公里的范围内暂停生产。高山汽车旅馆的生产井不得不在1987年被废弃,汽车旅馆只能使用燃气加热器。井下热交换器(DHE)用于提供所需的热量,但仅产生了22%的热量需求。实施空气提升以改善DHE的性能,从而使热量输出增加了125%。讨论了与早期试验相比热量输出的显着增加。提出了进一步改善DHE性能的建议。