The connection configurations of ground heat exchangers (GHEs) have a significant impact on the ground temperature and the performance of ground source heat pump (GSHP) systems. In this paper, the heating performance of a GSHP system implemented in a net zero-energy building with two different GHE connection configurations, including series and parallel connections, was experimentally and numerically investigated. A mathematical model was developed based on ANSYS fluent to analyze the thermal performance of the GHEs and the model was validated against the experimental data. The experimental results showed that the parallel configuration of the GHEs achieved a better heating performance when the mass flow rate was 2.58 kg.s(-1), as compared to that of the series configuration. The system heating performance with both series and parallel configurations of the GHEs increased with the decrease in the fluid flow rate under the same heating load condition. The pressure drop between the inlet and outlet of the GHEs with the series configuration was also higher when compared to that with the parallel configuration.
机译:地面热交换器(GHE)的连接配置对地面温度和地源热泵(GSHP)系统的性能有重大影响。在本文中,通过实验和数值研究了在具有两种不同的GHE连接配置(包括串联和并联)的净零能耗建筑物中实施的GSHP系统的加热性能。基于ANSYS fluent开发了一个数学模型来分析GHE的热性能,并根据实验数据对该模型进行了验证。实验结果表明,与串联结构相比,当质量流量为2.58 kg.s(-1)时,并联结构的GHEs具有更好的加热性能。在相同的加热负载条件下,随着流体流速的降低,GHE的串联和并联配置的系统加热性能都会提高。与并联配置相比,串联配置的GHE的入口和出口之间的压降也更高。

著录项

  • 来源
    《Geothermics》 |2019年第7期|20-30|共11页
  • 作者单位

    Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China|Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Shaanxi, Peoples R China;

    Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China;

    Univ Wollongong, Sustainable Bldg Res Ctr, Wollongong, NSW, Australia;

    Univ Wollongong, Sustainable Bldg Res Ctr, Wollongong, NSW, Australia;

    Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ground source heat pump; Ground heat exchanger; Connection configurations; Coefficient of performance;