Hydraulic Conductivity Testing of Geosynthetic Clay Liners (GCLs) Using the Constant Volume Method

机译:恒定体积法测试土工合成粘土衬里(GCL)的水力传导率

获取原文
获取原文并翻译 | 示例
           

摘要

Hydraulic conductivity tests were conduced using open and constant-volume permeation systems on specimens from a geosynthetic clay liner (GCL). Two constant volume (CV) systems were employed: the falling-head constant-volume (FHCV) system and the constant-head consant-volume (CHCV) system. A conventional burette system using pressurized air was employed for teh open system (OS) tests. The test results show that hydraulic conductivity tests can be conducted 30 or more times faster with the FHCV and CHCV systems than with an open system. Typically the permeation portion of the FHCV and CHCV tests can be conducted in one-half day.
机译:使用开放和恒定体积渗透系统对土工合成粘土衬里(GCL)的样品进行了水力传导性测试。使用了两个恒定体积(CV)系统:落头恒定体积(FHCV)系统和恒定头恒定体积(CHCV)系统。开放系统(OS)测试采用了使用加压空气的传统滴定管系统。测试结果表明,与开放式系统相比,FHCV和CHCV系统的水力传导率测试可以快30倍或更多倍。通常,FHCV和CHCV测试的渗透部分可以在半天之内进行。