Variaciones someras de la resistividad eléctrica a menudo dificultan la interpretación de datos de estudios eléctricos y electromagnéticos en términos de un subsuelo 1-D. Aquí interpretamos los datos de dos métodos de resistividad (sondeo eléctrico vertical, SEV) y perfilaje dipolo-dipolo) y dos métodos electromagnéticos (perfilaje de muy baja frecuencia-resistividad, VLF-R; y sondeo electromagnético transitorio, TEM) sobre tres heterogeneidades someras: un tubo metálico, una pared granítica aflorante y una cerca de alambre de púas. Aplicando varios algoritmos numéricos en 1-D, 2-D y 2.5-D en algunos casos estimamos la estructura del subsuelo, y en otros el efecto de las heterogeneidades laterales. Sólo en el caso de la pared granítica es aparente la necesidad del uso de un método 3-D para interpretar los datos TEM. El método VLF-R fue útil al detectar la presencia de las heterogeneidades que pudieron haber pasado desapercibidas por los otros métodos. Los métodos SEV y TEM resultaron ser complementarios en varios aspectos. Los datos de los SEV no fueron afectados por las heterogeneidades conductoras y la estructura somera estuvo mejor resuelta. Por otro lado, el método TEM no fue afectado por las altas resistencias de contacto y fue inmune al problema de equivalencia que afectó a los SEV. El tubo sí afecto al flujo de corriente galvánico, a pesar de su cubierta protectora. La cerca con postes metálicos produjo una intensa anomalía de VLF-R y afectó al sondeo TEM cercano. Las cercas con postes de madera no produjeron ninguna anomalía.%Shallow variations of electrical resistivity often interfere with the interpretation of data from electric and electromagnetic surveys in terms of a 1-D subsurface. We interpret data of two resistivity (vertical electric sounding, VES, and dipole-dipole profiling) and two electromagnetic methods (very low frequency-resistivity profiling, VLF-R, and transient electromagnetic, TEM, soundings) over three shallow inhomogeneities: a metallic pipe, an outcropping granite wall, and a barbed-wire fence. By applying several of 1-D, 2-D, and 2.5-D numerical algorithms we estimate the subsurface resistivity structure, and the perturbing effect of the lateral inhomogeneities. Only in the case of the granitic wall a need for a 3-D algorithm to model the TEM data was apparent. The VLF-R method was useful as it detected the presence of inhomogeneities that might have remained unnoticed by the other methods. The VES and TEM methods turned out to be complementary in several aspects. The VES data were not affected by the conductive inhomogeneities and the shallow resistivity structure was better resolved. On the other hand, the TEM method was not affected by high contact resistances and was immune to the equivalence problem affecting the VES data. Despite its impervious paint cover, the pipe perturbed the galvanic current flow. The presence of the fence with metallic posts produced a strong VLF-R anomaly and affected the neighboring TEM soundings. The fences with wooden posts produced no anomaly.
机译:电阻率的浅薄变化通常使得难以根据一维地下土壤来解释来自电学和电磁学研究的数据。在这里,我们从三种浅层异质性解释两种电阻率方法(垂直电测深,SEV)和偶极子-偶极子分布图以及两种电磁方法(非常低的低频电阻率分布,VLF-R和瞬变电磁测深,TEM)中的数据-金属管,露出的花岗岩墙和铁丝网。在某些情况下,在1-D,2-D和2.5-D中应用各种数值算法,我们可以估算地下土壤的结构,而在其他情况下,则可以估算横向非均质性的影响。仅在花岗岩墙的情况下,才需要使用3-D方法来解释明显的TEM数据。 VLF-R方法可用于检测其他方法可能遗漏的异质性。事实证明,SEV和TEM方法在几个方面是互补的。 SEV数据不受导电异质性的影响,浅层结构的分辨率更好。另一方面,TEM方法不受高接触电阻的影响,并且不受影响SEV的等效问题的影响。尽管有保护罩,但该管确实影响了电动电流。金属螺柱围栏产生强烈的VLF-R异常并影响附近的TEM测深。带有木桩的栅栏不会产生任何异常。%电阻率的浅薄变化通常会干扰一维地下电磁和电磁测量数据的解释。我们解释三种浅层不均匀性的两种电阻率(垂直电测深,VES和偶极子-偶极子分布图)和两种电磁方法(极低频电阻率分布,VLF-R和瞬变电磁,TEM,测深)的数据管道,露出的花岗岩墙和铁丝网围栏。通过应用一维,二维和2.5维数值算法,我们可以估算地下电阻率结构以及横向不均匀性的扰动效应。仅在花岗岩墙的情况下,才需要对TEM数据建模的3-D算法。 VLF-R方法很有用,因为它可以检测到其他方法可能仍未注意到的不均匀性。事实证明,VES和TEM方法在几个方面是互补的。 VES数据不受导电不均匀性的影响,浅层电阻率结构得到了较好的解析。另一方面,TEM方法不受高接触电阻的影响,并且不受影响VES数据的等效问题的影响。尽管其油漆覆盖层不透水,但管道仍扰动了电流。带有金属柱的栅栏的存在产生了强烈的VLF-R异常,并影响了附近的TEM测深。带有木桩的栅栏没有异常。

著录项

  • 来源
    《Geofisica internacional》 |2011年第4期|p.371-399|共29页
  • 作者单位

    Departamento de Geoffsica Aplicada Centra de Investigation Cientifica y Educacion Superior de Ensenada (CICESE) Carretera Ensenada-Tijuana 3918 Zona Playitas, 22860 Ensenada, B.C., Mexico;

    Departamento de Geofisica Aplicada Centra de Investigacion Cientifica y Educacion Superior de Ensenada (CICESE) Carretera Ensenada-Tijuana 3918 Zona Playitas, 22860 Ensenada, B.C., Mexico;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    shallow electrical inhomogeneities; TEM method; VLF method; VES method;

    机译:浅的电气不均匀性;TEM法;VLF方法;VES法;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号