Towards greener data centers with storage class memory

机译:借助存储级内存打造更环保的数据中心

获取原文
获取原文并翻译 | 示例

摘要

Studies have shown that much of today's data centers are over-provisioned and underutilized. Over-provisioning cannot be avoided as these centers must anticipate peak load with bursty behavior. Under-utilization, to date, has also been unavoidable as systems always had to be ready for that sudden burst of requests that loom just around the corner. Previous research has pointed to turning off systems as one solution, albeit, an infeasible one due to its irresponsiveness. In this paper, we present the feasibility of using new Storage Class Memory (SCM, which encompasses specific developments such as PCM, MRAM, or FeRAM) technology to turn systems on and off with minimum overhead. This feature is used to control systems on the whole (in comparison to the previous fine-grained component-wise control) in finer time scale for high responsiveness with minimized power lost to idleness. Our empirical study is done by executing real trace-like workloads on a prototype data center of embedded systems deploying FeRAM. We quantify the energy savings and performance trade-off by turning idle systems off. We show that our energy savings approach consumes energy in proportion to user requests with configurable quality of service. Finally, based on observations made on this data center, we discuss the requirements for real deployment.
机译:研究表明,当今的许多数据中心都被过度配置和未充分利用。无法避免过度配置,因为这些中心必须以突发行为预见峰值负载。迄今为止,利用不足一直是不可避免的,因为系统总是必须为即将到来的突发请求做好准备。先前的研究指出,将系统关闭是一种解决方案,尽管由于其无响应性,这是不可行的。在本文中,我们介绍了使用新的存储类内存(SCM,包括PCM,MRAM或FeRAM等特定开发技术)来以最小的开销打开和关闭系统的可行性。此功能用于在更精细的时间范围内对整个系统进行控制(与以前的细粒度组件控制相比),以实现高响应度,同时将因空闲而损失的功率降至最低。我们的实证研究是通过在部署FeRAM的嵌入式系统的原型数据中心上执行真实的类似跟踪的工作负载来完成的。我们通过关闭空闲系统来量化节能和性能折衷。我们证明,我们的节能方法与可配置服务质量的用户需求成比例地消耗能量。最后,基于对该数据中心的观察,我们讨论了实际部署的要求。

著录项

  • 来源
    《Future generation computer systems 》 |2013年第8期| 1969-1980| 共12页
  • 作者单位

    Department of Computer Engineering, Hongik University, Seoul, Republic of Korea;

    Department of Computer Engineering, Hongik University, Seoul, Republic of Korea;

    Department of Computer Engineering, Hongik University, Seoul, Republic of Korea;

    Division of Information and Computer Science, Dankook University, Yongin, Republic of Korea;

    School of Computer Science, University of Seoul, Republic of Korea;

    Department of Computer Engineering, Hongik University, Seoul, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Power management; Servers; Idleness; SCM; NVRAM;

    机译:能源管理;服务器;懒惰;单片机NVRAM;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号