首页> 外文期刊>Fusion Science and Technology >Neutral Transport and Particle Balance in Hanbit Magnetic Mirror Device
【24h】

Neutral Transport and Particle Balance in Hanbit Magnetic Mirror Device

机译:Hanbit磁镜装置中的中性传输和粒子平衡

获取原文
获取原文并翻译 | 示例
           

摘要

According to the recent low gas-puff experiments in Hanbit magnetic mirror device, the achievable ion temperature is limited largely by neutral content. For discharges with the low gas-puff with the pre-ionization technique, higher ion temperature is estimated compared to the high gas-puff case. Neutral transport and corresponding particle balance in this low gas-puff discharges in Hanbit are analyzed with the two-dimensional Monte-Carlo simulation code coupled with a simple parallel plasma confinement formula. The radial ion temperature and power loss profiles are also derived. The global particle balance is between the plasma pumping and the recycling processes, hence the initially puffed amount of gas has negligible contribution to the total particle source.
机译:根据最近在Hanbit磁镜装置中进行的低气吹实验,可达到的离子温度在很大程度上受中性含量的限制。对于采用预电离技术的低气嘴放电,与高气嘴情况相比,预计离子温度更高。利用二维蒙​​特卡洛模拟代码和简单的平行等离子体约束公式,分析了汉比特低气体排放中的中性传输和相应的颗粒平衡。还导出了径向离子温度和功率损耗曲线。总体颗粒平衡介于等离子泵送和再循环过程之间,因此,最初喷射的气体量对总颗粒源的贡献可忽略不计。