首页> 外文期刊>Fusion Engineering and Design >Safety of fusion magnets: Pressure impact on arcing in model experiments to high-current arcs propagating along the busbars of large fusion magnet coils
【24h】

Safety of fusion magnets: Pressure impact on arcing in model experiments to high-current arcs propagating along the busbars of large fusion magnet coils

机译:聚变磁体的安全性:模型实验中的电弧放电压力对沿大型聚变磁体线圈的母线传播的大电流电弧的影响

获取原文
获取原文并翻译 | 示例
       

摘要

The paper reports the results of the latest experiments to support the development and validation of the numerical model for high-current arcs at the power cables (busbars) to the toroidal field (TF) coils. The busbar arcs have significant potential of danger in case of an accident due to the huge inductive energy of about 40 GJ stored permanently inside the TF coils. In a worst case these arcs may propagate to and penetrate the cryostat wall. The experiments were set up to understand the propagation and damage potential of such arcs. The present work investigates the influence of residual pressure on arcing.
机译:本文报告了最新实验的结果,以支持开发和验证动力电缆(母线)到环形磁场(TF)线圈的大电流电弧的数值模型。由于永久存储在TF线圈中的大约40 GJ的巨大感应能量,在发生事故的情况下,母线电弧具有很大的潜在危险。在最坏的情况下,这些电弧会传播到低温恒温器壁并穿透低温恒温器壁。进行实验是为了了解此类电弧的传播和潜在损坏。目前的工作调查残余压力对电弧的影响。

著录项

  • 来源
    《Fusion Engineering and Design》 |2010年第12期|p.1875-1879|共5页
  • 作者

    Dmitry Klimenko; Volker Pasler;

  • 作者单位

    Forschungszentrum Karlsruhe, P.O. Box 3640, D-76021 Karlsruhe, Germany;

    Forschungszentrum Karlsruhe, P.O. Box 3640, D-76021 Karlsruhe, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    iter; safety; arc; busbar; magnet coils;

    机译:迭代;安全;电弧;母线;电磁线圈;