Central, retractable tubes are proposed in several Upper Port Plugs (UPPs) designs for ITER, to enable fast exchange of specific components of diagnostics housed in these UPPs. This paper investigates into possible designs to enable the efficient handling of tubes. The feasibility of tube handling is analysed by first reviewing the designs drivers. Several concepts for handling of the tube are proposed, exploring the limits described by the design drivers. Suggestions are presented for tube integration into the UPP design, concerning the tube mounting into the UPP, the load takeover and coping with the thermal elongation. It is found that the handling of tubes is feasible but still requires a lot of system level integration. Also, the added value of a tube as a feature in an UPP design to the availability of the subsystem the UPP is a part of, is questionable and needs further assessment on ITER system level.
机译:在几种用于ITER的上端口塞(UPP)设计中提出了中央可伸缩管,以便能够快速更换这些UPP中包含的诊断程序的特定组件。本文研究了可能的设计以实现管的有效处理。首先检查设计驱动因素来分析管子处理的可行性。提出了几种处理管的概念,探索了设计驱动因素所描述的极限。提出了将管子集成到UPP设计中的建议,涉及将管子安装到UPP中,负载接管以及应对热伸长的建议。发现管的处理是可行的,但是仍然需要大量的系统级集成。而且,作为UPP设计中功能的一根管子,其附加值对UPP所包含的子系统的可用性是可疑的,需要在ITER系统级进行进一步评估。

著录项

  • 来源
    《Fusion Engineering and Design》 |2011年第11期|p.2060-2063|共4页
  • 作者单位

    FOM-lnstitutefor Plasma Physics Rijnhuizen. Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, P.O. Box 1207,3430 BE Nieuwegein. The Netherlands;

    FOM-lnstitutefor Plasma Physics Rijnhuizen. Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, P.O. Box 1207,3430 BE Nieuwegein. The Netherlands;

    FOM-lnstitutefor Plasma Physics Rijnhuizen. Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, P.O. Box 1207,3430 BE Nieuwegein. The Netherlands;

    TNO Science & Industry. Partner in ITER-NL. P.O. Box 155.2600 AD Delft. The Netherlands;

    Institut fuer Energieforschung - Plasmaphysik. Forschungszentrum Juelich Gmbh. Association EURATOM-FZJ. Member of Trilateral Euregio Cluster. 52425 Juelich. Germany;

    Institut fuer Energieforschung - Plasmaphysik. Forschungszentrum Juelich Gmbh. Association EURATOM-FZJ. Member of Trilateral Euregio Cluster. 52425 Juelich. Germany;

    ITER Organization. Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul-lez-Durance Cedex. France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    tube; upper port plug; diagnostic; handling; hot cell facility; shut down;