首页> 外文期刊>Fusion Engineering and Design >Design and analysis of the IFMIF-EVEDA beam dump cooling system
【24h】

Design and analysis of the IFMIF-EVEDA beam dump cooling system

机译:IFMIF-EVEDA束流冷却系统的设计与分析

获取原文
获取原文并翻译 | 示例
       

摘要

The IFMIF-EVEDA beam dump is designed to stop a 9 MeV, 125 mA continuous wave deuteron beam that deposits along its surface a total of 1.125 MW. The beam dump design is based on a 2.5 m long copper cone whose inner surface absorbs the beam. This piece is cooled by water flowing at high velocity through the annular channel formed between it and a second piece (shroud) made of four truncated cones of slightly different slopes. In this paper the beam dump cooling system will be briefly described, and the relevant 1D and 3D results will be presented paying especial attention to the computational fluid dynamics results.
机译:IFMIF-EVEDA光束收集器设计为停止9 MeV,125 mA连续波氘核光束,该光束沿其表面沉积总计1.125 MW。光束收集器设计基于一个2.5 m长的铜锥,该铜锥的内表面吸收光束。该部件被高速流动的水冷却,该水流经它和第二部件(护罩)之间形成的环形通道,该第二部件由四个略有不同斜率的截头圆锥体制成。本文将简要介绍束流冷却系统,并介绍相关的一维和三维结果,尤其要注意流体动力学的计算结果。

著录项

  • 来源
    《Fusion Engineering and Design》 |2012年第4期|332-335|共4页
  • 作者单位

    CIEMAT, Avd Complutense 22,28040 Madrid. Spain;

    CIEMAT, Avd Complutense 22,28040 Madrid. Spain;

    CIEMAT, Avd Complutense 22,28040 Madrid. Spain;

    CIEMAT, Avd Complutense 22,28040 Madrid. Spain;

    CIEMAT, Avd Complutense 22,28040 Madrid. Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    IFMIF-EVEDA; beam dump;

    机译:IFMIF-EVEDA;光束转储;
  • 入库时间 2022-08-18 00:39:17