首页> 外文期刊>Fusion Engineering and Design >Structural analysis of the ITER Vacuum Vessel regarding 2012 ITER Project-Level Loads
【24h】

Structural analysis of the ITER Vacuum Vessel regarding 2012 ITER Project-Level Loads

机译:关于2012年ITER项目级负荷的ITER真空容器的结构分析

获取原文
获取原文并翻译 | 示例
       

摘要

A revision of the ITER Project-Level Load Specification (to be used for all systems of the ITER machine) was implemented in April 2012. This revision supports ITER's licensing by accommodating requests from the French regulator to maintain consistency with the plasma physics database and our present understanding of plasma transients and electro-magnetic (EM) loads, to investigate the possibility of removing unnecessary conservatism in the load requirements and to review the list and definition of incidental cases. The purpose of this paper is to present the impact of this 2012 revision of the ITER Project-Level Load Specification (LS) on the ITER Vacuum Vessel (VV) loads and the main structural margins required by the applicable French code, RCC-MR.
机译:2012年4月,对ITER项目级负荷规范(将用于ITER机器的所有系统)进行了修订。此修订通过满足法国监管机构的要求以保持与等离子体物理数据库和我们的等离子体发生器的一致性,支持了ITER的许可。目前对等离子体瞬变和电磁(EM)负载的理解,以研究消除负载要求中不必要的保守性的可能性,并审查偶发事件的列表和定义。本文的目的是介绍ITER项目级负载规范(LS)的2012年修订版对ITER真空容器(VV)负载的影响以及适用的法国法规RCC-MR要求的主要结构裕量。

著录项

  • 来源
    《Fusion Engineering and Design》 |2014年第8期|1836-1842|共7页
  • 作者单位

    ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France;

    ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France;

    ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France;

    ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France;

    ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France;

    ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France;

    ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France;

    Assystem EOS, 117 rue Jacquard, L'Atrium, 84120 Pertuis, France;

    Assystem EOS, 117 rue Jacquard, L'Atrium, 84120 Pertuis, France;

    Assystem EOS, 117 rue Jacquard, L'Atrium, 84120 Pertuis, France;

    Assystem EOS, 117 rue Jacquard, L'Atrium, 84120 Pertuis, France;

    Assystem EOS, 117 rue Jacquard, L'Atrium, 84120 Pertuis, France;

    Sogeti High Tech, RE2,180 rue Rene Descartes, Le Millenium - Bat C, 13857 Aix en Provence, France;

    SOM Calcul - Groupe ORTEC, 121 ancien Chemin de Cassis - Immeuble Grand Pre, 13009 Marseille, France;

    SOM Calcul - Groupe ORTEC, 121 ancien Chemin de Cassis - Immeuble Grand Pre, 13009 Marseille, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ITER; Vacuum Vessel; Structural integrity; Analysis; Load; RCC-MR;

    机译:ITER;真空容器结构完整性;分析;加载;碾压混凝土;
  • 入库时间 2022-08-18 00:38:48