The assessment of the Shutdown Dose Rate (SDR) due to neutron activation is a major safety issue for fusion devices and in the last decade several benchmark experiments have been conducted at JET during Deuterium-Deuterium experiments for the validation of the numerical tools used in ITER nuclear analyses. The future Deuterium-Tritium campaign at JET (DTE2) will provide a unique opportunity to validate the codes under ITER-relevant conditions through the comparison between numerical predictions and measured quantities (C/E). For this purpose, a novel SDR experiment, described in the present work, is in preparation in the frame of the WPJET3-NEXP subproject within EUROfusion Consortium. The experimental setup has been accurately designed to reduce measurement uncertainties; spherical air-vented ionization chambers (ICs) will be used for on-line ex-vessel decay gamma dose measurements during JET shutdown following DT operations and activation foils have been selected for measuring the neutron fluence near ICs during operations. Active dosimeters (based on ICs) have been calibrated over a broad energy range (from about 30 keV to 1.3 MeV) with X and gamma reference beam qualities. Neutron irradiation tests confirmed the capability of active dosimeters of performing on-line decay gamma dose rate measurements, to follow gamma dose decay at the end of neutron irradiation as well as insignificant activation of the ICs. (C) 2017 The Authors. Published by Elsevier B.V.
机译:中子活化引起的关机剂量率(SDR)的评估是聚变设备的主要安全问题,在过去的十年中,JET在氘-氘实验期间进行了几项基准实验,以验证ITER中使用的数值工具核分析。未来在JET(DTE2)开展的氘-rit运动将提供一个难得的机会,可以通过在数值预测和测量数量(C / E)之间进行比较,在与ITER相关的条件下验证代码。为此,在EUROfusion财团的WPJET3-NEXP子项目的框架内,正在准备本工作中描述的新颖的SDR实验。实验装置经过精确设计,以减少测量不确定度;球形空气排放电离室(IC)将在DT操作后的JET关闭期间用于在线前容器衰减伽马剂量测量,并且已选择激活箔片来测量操作期间IC附近的中子通量。有源剂量计(基于IC)已在X和γ参考光束质量下,在很宽的能量范围(约30 keV至1.3 MeV)上进行了校准。中子辐照测试证实了有源剂量计能够执行在线衰减伽马剂量率测量,以跟踪中子辐照结束时伽马剂量衰减以及IC的微不足道的激活。 (C)2017作者。由Elsevier B.V.发布

著录项

  • 来源
    《Fusion Engineering and Design》 |2017年第11期|1039-1043|共5页
  • 作者单位

    ENEA, Dept Fus & Nucl Safety Technol, I-00044 Rome, Italy|Univ Roma Tor Vergata, Dept Ind Engn, Via Politecn 1, I-00133 Rome, Italy;

    ENEA, Dept Fus & Nucl Safety Technol, I-00044 Rome, Italy;

    ENEA, Dept Fus & Nucl Safety Technol, I-00044 Rome, Italy;

    ENEA, Dept Fus & Nucl Safety Technol, I-00044 Rome, Italy;

    ENEA, Dept Fus & Nucl Safety Technol, I-00044 Rome, Italy|Univ Roma Tor Vergata, Dept Ind Engn, Via Politecn 1, I-00133 Rome, Italy;

    Karlsruhe Inst Technol, D-76344 Karlsruhe, Germany;

    ENEA, Dept Fus & Nucl Safety Technol, I-00044 Rome, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    JET; Shutdown dose rate; Occupational exposure in fusion; experiments; DTE2;