R2Smesh is a computational interface linking the Monte Carlo code MCNP and inventory code FISPACT for accurate shutdown dose rate (SDDR) analysis in fusion reactor. The superimposed mesh tally in MCNP has been introduced in its development effort for calculation of neutron flux and multi-group spectra. The resulting neutron flux is averaged within each mesh element as its gradient is omitted. The accuracy of final SDDR thus relies heavily on mesh resolution. To evaluate the influence of mesh resolution on SDDR, the sensitivity analysis has been conducted on JET and EU DEMO by using series of mesh with different voxel size. The convergence of SDDR was achieved and the optimum size of mesh voxel for JET and DEMO SDDR calculation were determined after compromising between the precision of result and high computational cost. By employing the optimum mesh resolution, the R2Smesh interface was validated through comparison with JET measurements. Afterwards it was applied on DEMO for global SDDR analysis to provide support for neutron and gamma induced shielding design.
机译:R2Smesh是链接蒙特卡罗代码MCNP和库存代码FISPACT的计算接口,用于在聚变反应堆中进行准确的停机剂量率(SDDR)分析。 MCNP中叠加的网格记数法在其用于计算中子通量和多族谱的开发工作中得到了介绍。由于省略了其梯度,因此所得的中子通量在每个网格元素内平均。因此,最终SDDR的精度在很大程度上取决于网格分辨率。为了评估网格分辨率对SDDR的影响,通过使用一系列不同体素尺寸的网格对JET和EU DEMO进行了敏感性分析。实现了SDDR的收敛,并且在结果精度和高计算成本之间取得了平衡,确定了用于JET和DEMO SDDR计算的网格体素的最佳大小。通过采用最佳网格分辨率,通过与JET测量进行比较来验证R2Smesh界面。之后,将其应用于DEMO进行全局SDDR分析,以支持中子和伽马感应屏蔽设计。

著录项

  • 来源
    《Fusion Engineering and Design》 |2018年第1期|15-23|共9页
  • 作者单位

    Univ Sci & Technol China, Sch Nucl Sci & Technol, Hefei 230026, Anhui, Peoples R China;

    Karlsruhe Inst Technol, Assoc KIT Euratom, Hermann von Helmholtz Pl 1, D-76344 Karlsruhe, Germany;

    Karlsruhe Inst Technol, Assoc KIT Euratom, Hermann von Helmholtz Pl 1, D-76344 Karlsruhe, Germany;

    Karlsruhe Inst Technol, Assoc KIT Euratom, Hermann von Helmholtz Pl 1, D-76344 Karlsruhe, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Shutdown dose rate; R2Smesh; Sensitivity; JET; DEMO;