During 1997 JET was operated for an extensive period using a D-T mixture (DTE1). Changes in the design and operation of diagnostic systems made over the years in preparation for this phase are described. A number of diagnostic techniques have been deployed to measure the deuterium and tritium content of the plasma during DTE1 and their results are compared. All diagnostics with a direct vacuum interface with the main vessel have been fitted with tritium compatible pumps and their exhaust gases have been re-routed to the active gas handling plant. All items on the torus which could lead to a significant leak in the event of failure, were required to have double containment. Therefore, all windows, and a majority of bellows and feedthroughs, were designed and installed with a double barrier. Heated fibre hoses were installed to transmit plasma light beyond the biological shield for spectroscopic purposes. Blind fibres and fibre loops were also installed to study the effects of higher neutron fluxes on these fibres. A radiation-hardened video camera was installed to monitor the plasma during the DTE1 discharges. Extra shielding was installed on a number of diagnostics to deal with the higher neutron fluxes during DTE1. The effect of neutron radiation on electronics in the Torus Hall was studied. During DTE1 the tritium fraction was measured at the edge and in the core using several diagnostic methods. High resolution Balmer α line spectroscopy gave a measurement typical of the plasma edge region. In the JET sub-divertor volume the tritium concentration of the neutral gas was
机译:在1997年期间,JET使用D-T混合物(DTE1)进行了广泛的运行。描述了为准备此阶段多年来在诊断系统设计和操作方面所做的更改。已经部署了许多诊断技术来测量DTE1期间血浆中氘和tri的含量,并对结果进行比较。所有与主容器具有直接真空接口的诊断仪均已安装了与compatible兼容的泵,其废气已重新路由至活性气体处理厂。圆环上所有可能在故障情况下导致严重泄漏的物品都必须有双重密封。因此,所有窗户以及大多数风箱和馈通孔均设计并安装了双层屏障。为了光谱目的,安装了加热的纤维软管以将血浆光传输到生物屏蔽之外。还安装了盲纤维和纤维环,以研究较高中子通量对这些纤维的影响。安装了防辐射摄像机,以监控DTE1放电期间的等离子体。在许多诊断程序上安装了额外的屏蔽,以应对DTE1期间较高的中子通量。研究了中子辐射对Torus Hall中电子设备的影响。在DTE1期间,使用几种诊断方法在边缘和岩心中测量了fraction含量。高分辨率巴尔默α线光谱仪提供了等离子体边缘区域的典型测量值。在JET分偏器体积中,中性气体的concentration浓度为

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号