首页> 外文期刊>Fusion Engineering and Design >Test Results of Active Thermography Method for Plasma-Wall Interaction Studies on the KTM Tokamak
【24h】

Test Results of Active Thermography Method for Plasma-Wall Interaction Studies on the KTM Tokamak

机译:基于KTM Tokamak的等离子体壁交互研究的主动热成像方法的测试结果

获取原文
获取原文并翻译 | 示例
       

摘要

The paper describes the main experimental results of testing the method of thermographic measurements on a test bench with a plasma-beam facility. The developed method is intended to improve the accuracy of surface temperature measurements of candidate materials of the first wall of future thermonuclear reactors during investigations on the KTM tokamak. The method is based on the use of an external infrared radiation to directly determine the changes in the body reflectivity and a corresponding increase in the accuracy of the temperature measurement by a thermographic camera by recalculating and correcting the value of the emissivity. Resulting curves of changes in reflectivity (emissivity) obtained from the measurements are close to the real values within the inaccuracy of the method. The results of the test demonstrated the efficiency of the proposed method.
机译:本文介绍了用等离子体光束设施测试测试台上的热成像测量方法的主要实验结果。开发的方法旨在改善在KTM Tokamak上未来热核反应器的第一壁的候选材料的表面温度测量的精度。该方法基于外部红外辐射的使用,通过重新计算和校正发射率的值,直接确定主体反射率的变化和热量测量的温度测量精度的相应增加。从测量结果获得的反射率(发射率)的变化曲线接近该方法的不准确内的实际值。测试结果证明了所提出的方法的效率。