Ensuring an accurate visualization of incident electron beam in high heat flux test facilities is a key to improve the monitoring of high-heat flux (HHF) tests carried out in view to verify the thermo-mechanical performance of components. Recent progress in X-ray imaging sensors R&D made them well-adapted for such monitoring, in particular in the case of tested components with complex shapes. This paper describes the innovative X-ray imaging diagnostic implemented in both the TSEFEY-M and IDTF facilities (Efremov Institute, Saint-Petersburg, Russia) to improve the accuracy of ITER in-vessel components HHF tests monitoring.
机译:确保在高热通量测试设备中入射电子束的准确可视化是改进监视高热通量(HHF)测试以验证部件的热机械性能的关键。 X射线成像传感器研发的最新进展使它们非常适合于这种监视,特别是在测试形状复杂的组件的情况下。本文介绍了在TSEFEY-M和IDTF设施(俄罗斯圣彼得堡的埃夫雷莫夫研究所)中实施的创新X射线成像诊断,以提高ITER船上组件HHF测试监测的准确性。