首页> 外文期刊>Fusion Engineering and Design >Hot Helium Leak Test of ITER blanket shield block
【24h】

Hot Helium Leak Test of ITER blanket shield block

机译:ITER毯式屏蔽块的热氦气泄漏测试

获取原文
获取原文并翻译 | 示例
           

摘要

To ensure successful operation of the International Thermonuclear Experimental Reactor (ITER), the blanket shield block modules are required to demonstrate the vacuum performance by Hot Helium Leak Test (HHLT), which is performed at the relevant ITER operational conditions and is one of the Factory Acceptance Tests (FAT) of the product. A specific facility is developed in China to perform these demanding tests, which has a 10 m(3) vacuum chamber to accommodate the large size of shield blocks and achieved an overall system leak detect sensitivity of 7.19 x 10(-11) Pa. m(3)/s at 235 degrees C. A full-scale proto-type of ITER shield block was tested in this facility, which showed maximum helium leak rate is less than 1.74 x 10(-10) Pa. m(3)/s under 4.2 MPa pure helium gas pressure at 235 degrees C. The HHLT was performed with cyclic pressure and temperature process and the results were given in this paper. The behavior of the background leak rate during these processes were also monitored and discussed.
机译:为确保国际热核实验堆(ITER)的成功运行,要求毯式屏蔽模块通过热氦气泄漏测试(HHLT)展示真空性能,该测试是在相关ITER运行条件下进行的,并且是工厂之一产品的验收测试(FAT)。中国已开发出专门的设备来执行这些苛刻的测试,该设备具有一个10 m(3)的真空室,可容纳大尺寸的屏蔽块,并且整个系统的泄漏检测灵敏度达到7.19 x 10(-11)Pa。m在235摄氏度下为(3)/ s。在此设备中测试了ITER屏蔽块的完整原型,该模型显示最大氦气泄漏率小于1.74 x 10(-10)Pa。m(3)/在235℃的4.2 MPa纯氦气体压力下进行s。HHLT在循环压力和温度下进行,本文给出了结果。在这些过程中,本底泄漏率的行为也得到了监测和讨论。