首页> 外文期刊>Fusion Engineering and Design >Type tests of counter pulse circuits for the ITER fast discharge units
【24h】

Type tests of counter pulse circuits for the ITER fast discharge units

机译:ITER快速放电装置的反脉冲电路的型式试验

获取原文
获取原文并翻译 | 示例
       

摘要

Fast Discharge Units (FDU) forming part of the ITER coil power supply systems are intended for protection of superconductive coils by extracting the energy stored in the magnet system in case of a quench or other abnormal events. It will be provided by opening the coil current circuits by normally closed circuit breakers, thus diverting the current into discharge resistors. The interruption of DC currents in the inductive circuits is provided with the help of counter pulse circuits (CPC), the discharge of which in the direction opposite to the coil current direction ensures the arc extinguishing in the circuit breakers.The paper describes the design of two CPC modifications and presents the results of the type tests carried out on CPC full-scale prototypes. The successful results of the tests demonstrated the working efficiency of CPCs, confirmed their compliance with the design requirements and gave green light to the manufacturing of these devices to be delivered to the ITER Site.
机译:构成ITER线圈电源系统一部分的快速放电单元(FDU)用于在发生失超或其他异常事件时通过提取存储在磁体系统中的能量来保护超导线圈。通过使用常闭断路器断开线圈电流电路,从而将电流转移到放电电阻器中,可以提供该功能。借助反脉冲电路(CPC)可以中断感应电路中的直流电流,该反脉冲电路的放电方向与线圈电流方向相反,从而确保了断路器中的电弧熄灭。两次CPC修改,并介绍了在CPC全面原型上进行的类型测试的结果。测试的成功结果证明了CPC的工作效率,确认了CPC符合设计要求,并为将要交付ITER站点的这些设备的制造开了绿灯。