首页> 外文期刊>Fusion Engineering and Design >Digital valve system for ITER remote handling - Design and prototype testing
【24h】

Digital valve system for ITER remote handling - Design and prototype testing

机译:用于ITER远程处理的数字阀系统-设计和原型测试

获取原文
获取原文并翻译 | 示例
       

摘要

ITER-RH system is used to exchange the divertor's 54 cassette assemblies in the vessel. Water hydraulics and servo valves are currently used in the task but concerns exist with robustness and availability of suitable components. An alternative option is to use digital technology where on/off valves and intelligent control is used to produce proportional output. So far, no proper high-pressure on/off valves existed in the market and therefore a new concept was developed and tested with promising results. A mock-up of the remote handling system was used as test bench. The system was simulated in order to dimension the valve system and to tune the valve controller. A complete valve package with 16 prototype on/off valves and a manifold was manufactured and long-term tests of 60 working days was conducted. A new level of performance was demonstrated throughout the tests as tracking accuracies were approximately ten times better than with servo valve. Although some design faults where detected and system had faulty components, tracking accuracy was very good. Tracking and positioning capability of digital valve system exceeds all requirements and seems applicable for ITER RH application.
机译:ITER-RH系统用于更换容器中分流器的54个暗盒组件。当前在任务中使用水液压和伺服阀,但存在对耐用性和合适组件可用性的担忧。另一种选择是使用数字技术,其中开/关阀和智能控制用于产生比例输出。到目前为止,市场上尚无合适的高压开关阀,因此,开发了一种新的概念并进行了测试,结果令人满意。远程处理系统的模型被用作测试平台。对系统进行了仿真,以便确定阀门系统的尺寸并调整阀门控制器。制造了具有16个原型开关阀和歧管的完整阀组件,并进行了60个工作日的长期测试。在整个测试过程中表现出新的性能水平,因为跟踪精度大约是伺服阀的十倍。尽管在某些检测到的系统设计错误中,系统存在故障,但跟踪精度还是很高的。数字阀系统的跟踪和定位功能超出了所有要求,似乎适用于ITER RH应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号