Measurement of n = 1 locked mode using locked mode coils in KSTAR

机译:使用KSTAR中的锁定模式线圈测量n = 1锁定模式

获取原文
获取原文并翻译 | 示例
       

摘要

The n = 1 static or quasi-static magnetohydrodynamic (MHD) mode such as locked mode (LM) is measured by using LM coils in KSTAR. The delicate signal processing scheme is established to measure the time-evolution of the amplitude and phase of n = 1 LM even low mode-signal sensitivity than non-mode poloidal field sources of LM coils. The effective area of each LM coils are calibrated by comparing the obtained signal and calculated signal responding to a current in the poloidal field (PF) coils without plasma. To pick up only the plasma response two kinds of analytic solutions - the lumped circuit model and the autoregressive with exogenous terms (ARX) model - are introduced to estimate the induced signals to the LM coils from the non-axisymmetric in-vessel coils (IVCs) including its eddy current effect. The developed mode diagnostic method is applied to KSTAR disrupted plasmas and shows consistency with other diagnostics.
机译:通过使用KSTAR中的LM线圈来测量n = 1静态或准静态磁流体动力学(MHD)模式,例如锁定模式(LM)。建立了精细的信号处理方案,以测量n = 1 LM的幅度和相位的时间演化,甚至比LM线圈的非模式极向场源都低的模式信号灵敏度。通过比较获得的信号和响应于无等离子体的极向场(PF)线圈中电流的计算信号,可以校准每个LM线圈的有效面积。为了仅吸收等离子体响应,引入了两种分析解决方案-集总电路模型和带有外生项的自回归(ARX)模型-来估计从非轴对称容器内线圈(IVC)到LM线圈的感应信号),包括其涡流效应。开发的模式诊断方法适用于KSTAR破坏血浆,并显示出与其他诊断方法的一致性。