首页> 外文期刊>Forensic Toxicology >Simultaneous analysis of sildenafil, vardenafil, tadalafil, and their desalkyl metabolites in human whole blood and urine by isotope dilution LC–MS–MS
【24h】

Simultaneous analysis of sildenafil, vardenafil, tadalafil, and their desalkyl metabolites in human whole blood and urine by isotope dilution LC–MS–MS

机译:同位素稀释LC-MS-MS同时分析人全血和尿液中西地那非,伐地那非,他达拉非及其脱烷基代谢产物

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Given that there are many autopsy cases in which erectile dysfunction (ED) treatment drugs can be detected from elderly men who are diagnosed to have died of cardiovascular disorders, the degree of cardiovascular risk posed by ED treatment drugs is still controversial. Moreover, counterfeit ED drugs or illegal dietary supplements containing ED drugs are also threats to public health. In this study, we established a detailed procedure for simultaneous analysis of typical ED drugs (sildenafil, vardenafil, tadalafil) and their metabolites in human blood and urine by isotope dilution liquid chromatography-tandem mass spectrometry (LC–MS–MS). Each sample of whole blood and urine containing the three ED treatment drugs, their metabolites, and deuterated internal standards (ISs) was diluted with alkalinized water, loaded onto an Oasis HLB cartridge, washed with dilute ammonium hydroxide solution, and eluted with chloroform. The eluate was acidified with methanol and concentrated HCl and evaporated to dryness. The resulting residue was reconstituted with methanol and mobile phase solution, and 5 μl of the solution was injected into an LC–MS–MS instrument. The determinations were made by multiple reaction monitoring using each product ion. The recovery rates of the drugs, metabolites, and ISs from whole blood and urine ranged from 80.7 to 127%. Good linearity was obtained for all drugs and their metabolites in the range of 1–100 ng/ml in whole blood and urine with correlation coefficients greater than 0.99. The detection limits (signal-to-noise ratio = 3) for all compounds were not higher than 0.05 ng/ml. Intraday and interday accuracy and precision data were also satisfactory for all compounds in whole blood and urine. Actual measurements of sildenafil and N-desmethyl sildenafil were also demonstrated by analysis of whole blood and urine specimens from two male volunteers after ingestion of a 25-mg tablet of sildenafil.
机译:鉴于在很多尸检病例中,可以从诊断出死于心血管疾病的老年男性中检出勃起功能障碍(ED)治疗药物,因此ED治疗药物带来的心血管风险程度仍存在争议。此外,伪造的ED药物或含有ED药物的非法膳食补充剂也对公共健康构成威胁。在这项研究中,我们建立了通过同位素稀释液相色谱-串联质谱法(LC-MS-MS)同时分析人血液和尿液中的典型ED药物(西地那非,伐地那非,他达拉非)及其代谢物的详细程序。将含有三种ED治疗药物,它们的代谢物和氘代内标(ISs)的全血和尿液的每个样品用碱化水稀释,装在Oasis HLB柱上,用稀氢氧化铵溶液洗涤,再用氯仿洗脱。洗脱液用甲醇和浓HCl酸化并蒸发至干。产生的残留物用甲醇和流动相溶液重构,并将5μl溶液注入LC-MS-MS仪器中。通过使用每种产物离子的多反应监测进行测定。从全血和尿液中回收的药物,代谢物和IS的回收率在80.7至127%之间。所有药物及其代谢产物在全血和尿液中均具有良好的线性关系,范围为1–100 ng / ml,相关系数大于0.99。所有化合物的检出限(信噪比= 3)均不高于0.05 ng / ml。对于全血和尿液中的所有化合物,日间和日间准确性和精密度数据也令人满意。西地那非和N-去甲基西地那非的实际测量结果还通过分析摄入25mg西地那非片剂的两名男性志愿者的全血和尿液样本得到证实。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号