首页> 外文期刊>Fire Technology >Unprotected Floor Assemblies and Tenability Conditions in a Test House Under Two Basement Fire Scenarios
【24h】

Unprotected Floor Assemblies and Tenability Conditions in a Test House Under Two Basement Fire Scenarios

机译:两种地下火灾情况下测试室内的未保护地板组件和耐久性条件

获取原文
获取原文并翻译 | 示例
       

摘要

A full-scale experimental program was undertaken to study the impact of two basement fire scenarios on the structural integrity of unprotected floor assemblies above a basement and the tenability conditions in a test facility representing a typical two-storey detached single-family house with a basement. The experiments utilized relatively severe, fast-growing fires set in the basement, which had an unprotected (unfinished) ceiling, to challenge the structural integrity of the floor system above the basement, which provides the normal egress route on the first storey for occupants. A range of floor assemblies constructed with various types of engineered floor joists and trusses (including wood I-joists, steel C-joists, metal plate wood trusses and metal web wood trusses) and with solid-wood joists, were used in the experiments with the basement side unprotected (unsheathed). Potential exposure to toxic gases, heat and smoke obscuration under the test conditions was analyzed to estimate the time available for escape. The results help establish the sequence of fire events such as fire initiation, smoke alarm activation, onset of untenable conditions, and structural failure of the floor assembly above the basement to understand how these factors affect the ability of occupants on the upper storeys to escape in the event of a basement fire.
机译:进行了一项全面的实验计划,研究了两种地下室火灾对地下室上方无保护地板组件的结构完整性的影响,以及在代表典型的两层独立单层住宅和地下室的测试设施中的耐久条件。 。实验利用地下室中设置的相对严峻,快速增长的火灾,该火灾具有未保护的(未完成的)天花板,以挑战地下室上方地板系统的结构完整性,从而为居住者提供了第一层的正常出口路线。实验中使用了一系列由各种类型的工程地板托梁和桁架(包括木工I型托梁,钢制C型托梁,金属板木桁架和金属腹板木桁架)以及实木托梁构成的地板组件。地下室一侧没有保护(无护套)。分析了在测试条件下可能暴露于有毒气体,热和烟雾的状态,以估计可逃生的时间。结果有助于确定火灾事件的发生顺序,例如起火,启动烟雾报警器,发生不可持续的状况以及地下室上方地板组件的结构故障,以了解这些因素如何影响上层居住者逃生的能力。地下室起火。

著录项

  • 来源
    《Fire Technology》 |2011年第3期|p.631-664|共34页
  • 作者单位

    Fire Research Program, Institute for Research in Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6, Canada;

    Fire Research Program, Institute for Research in Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6, Canada;

    Fire Research Program, Institute for Research in Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6, Canada;

    Fire Research Program, Institute for Research in Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6, Canada;

    Fire Research Program, Institute for Research in Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6, Canada;

    Fire Research Program, Institute for Research in Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    home fire safety; smoke alarms; tenability; engineered floor assemblies;

    机译:家庭消防安全;烟雾报警器;坚韧工程地板组件;