首页> 外文期刊>Fire and materials >The Effects of Subfloor and Insulation Type and Thickness on the Fire Resistance of Small-scale Floor Assemblies
【24h】

The Effects of Subfloor and Insulation Type and Thickness on the Fire Resistance of Small-scale Floor Assemblies

机译:地板和保温材料类型及厚度对小型地板组件耐火性的影响

获取原文
获取原文并翻译 | 示例
       

摘要

This paper discusses the results of 28 fire resistance tests conducted on unloaded insulated and non-insulated, small-scale frame floor assemblies using the ULC/ASTM fire exposure time-temperature curve. The frames used include either solid wood joist, wood I-joist, parallel-chord wood truss or steel C-joists. Temperatures were measured throughout the assemblies. All frames were protected on the fire-exposed side by Type X gypsum board, 16 mm thick. Parameters investigated in this study include the effects of subfloor type (plywood and oriented strand board), insulation type (glass, rock and cellulose) and insulation thickness (90 mm, 180 mm and full cavity). The impact of these parameters on the fire resistance performance of small-scale floor assemblies is discussed.
机译:本文讨论了使用ULC / ASTM火灾暴露时间-温度曲线在空载绝缘和非绝缘小型框架地板组件上进行的28项耐火测试结果。使用的框架包括实木托梁,I型木托梁,平行弦木桁架或C型钢托梁。在整个组件中测量温度。所有框架的火面均通过16毫米厚的X型石膏板保护。在这项研究中研究的参数包括地板类型(胶合板和定向刨花板),绝缘类型(玻璃,岩石和纤维素)和绝缘厚度(90 mm,180 mm和全腔)的影响。讨论了这些参数对小型地板组件耐火性能的影响。